.
Development status:
New development
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Acquisition/2D/NI/ImgAnalogGrabber
Contact:
Class Description
The device grabs images from a NI1409 acquisition board
Families: Acquisition
Key words: - 2D
Language: Cpp
Contact:
Class interface
Attributes:
Name | Description |
---|---|
ActiveChannelScalar: DevUShort | — |
ModeScalar: DevUShort | — |
BlackRefLevelScalar: DevDouble | — |
WhiteRefLevelScalar: DevDouble | — |
ShutterDelayScalar: DevDouble | — |
ExposureTimeScalar: DevDouble | — |
RefreshingPeriodScalar: DevDouble | — |
ImageImage: DevShort | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
AutoAdjustRefLevelsInput: DevVoid Output: DevVoid |
auto adjust the white reference level to adapt the dynamic of the image to the resolution |
SetROIInput: DevVarULongArray Output: DevVoid |
specify a Region Of Interest in the image |
FullROIInput: DevVoid Output: DevVoid |
resets any previously specified ROI |
GetROIInput: DevVoid Output: DevVarULongArray |
gives the current ROI used |
SaveCurrentSettingsInput: DevVoid Output: DevVoid |
saves the current configuration parameters to the Tango database |
OpenInput: DevVoid Output: DevVoid |
opens and locks the hardware interface |
CloseInput: DevVoid Output: DevVoid |
closes and unlock the video interface |
StartInput: DevVoid Output: DevVoid |
launch the image acquisition |
StopInput: DevVoid Output: DevVoid |
stops the video acquisition |
ToggleImageFreezingInput: DevVoid Output: DevVoid |
None. |
Pipes:
Properties:
Name | Description |
---|---|
Channel3SoftTrigPeriodDevDouble | — |
ActiveChannelDevShort | — |
Channel0ModeDevShort | — |
Channel0RefLevelBlackDevDouble | — |
Channel0RefLevelWhiteDevDouble | — |
Channel0ShutterDelayDevDouble | — |
Channel0ShutterExposureDevDouble | — |
Channel0SoftTrigPeriodDevDouble | — |
Channel1ModeDevShort | — |
Channel1RefLevelBlackDevDouble | — |
Channel1RefLevelWhiteDevDouble | — |
Channel1ShutterDelayDevDouble | — |
Channel1ShutterExposureDevDouble | — |
Channel1SoftTrigPeriodDevDouble | — |
Channel2ModeDevShort | — |
Channel2RefLevelBlackDevDouble | — |
Channel2RefLevelWhiteDevDouble | — |
Channel2ShutterDelayDevDouble | — |
Channel2ShutterExposureDevDouble | — |
Channel2SoftTrigPeriodDevDouble | — |
Channel3ModeDevShort | — |
Channel3RefLevelBlackDevDouble | — |
Channel3RefLevelWhiteDevDouble | — |
Channel3ShutterDelayDevDouble | — |
Channel3ShutterExposureDevDouble | — |
InterfaceNameDevString | — |
UseAsyncGrabbingDevBoolean | — |
AutoStartDevBoolean | — |
Please log in to comment.
Generated
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:23 Feb 2017, 9:16 a.m.