Class Description
Total pressure gauge and controller
Families: Vacuum
Key words:
Platform: All Platforms
Language: Cpp
Contact: marco.demarco@elettra.trieste.it
Hardware
Manufacturer: Pfeiffer
Product:
Tpg 256 a
Bus: Serial Line
Class interface
Attributes:
Name | Description |
---|---|
Name_0Scalar: DevString | — |
Name_1Scalar: DevString | — |
Name_2Scalar: DevString | — |
Name_3Scalar: DevString | — |
Name_4Scalar: DevString | — |
Name_5Scalar: DevString | — |
Pressure_0Scalar: DevDouble | — |
Pressure_1Scalar: DevDouble | — |
Pressure_2Scalar: DevDouble | — |
Pressure_3Scalar: DevDouble | — |
Pressure_4Scalar: DevDouble | — |
Pressure_5Scalar: DevDouble | — |
State_0Scalar: DevState | — |
State_1Scalar: DevState | — |
State_2Scalar: DevState | — |
State_3Scalar: DevState | — |
State_4Scalar: DevState | — |
State_5Scalar: DevState | — |
Status_0Scalar: DevString | — |
Status_1Scalar: DevString | — |
Status_2Scalar: DevString | — |
Status_3Scalar: DevString | — |
Status_4Scalar: DevString | — |
Status_5Scalar: DevString | — |
DeviceStateScalar: DevUChar | — |
SetPointStatusSpectrum: DevBoolean | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
SensorOnInput: DevShort Channel [0,5] Output: DevVoid |
Start measuring channel n |
SensorOffInput: DevShort Channel [0,5] Output: DevVoid |
Stop measuring channel n |
WriteLowerThresholdInput: DevVarDoubleArray Setpoint, Pressure Setpoint 0 -> Switching function A 1 -> Switching function B 2 -> Switching function C 3 -> Switching function D 4 -> Switching function E 5 -> Switching function F Pressure [1.0E-11, 9.9E+3] Output: DevVoid |
Set setpoint lower threshold |
ReadLowerThresholdInput: DevShort Setpoint 0 -> Switching function A 1 -> Switching function B 2 -> Switching function C 3 -> Switching function D 4 -> Switching function E 5 -> Switching function F Output: DevDouble Pressure |
Get setpoint lower threshold |
WriteUpperThresholdInput: DevVarDoubleArray Setpoint, Pressure Setpoint 0 -> Switching function A 1 -> Switching function B 2 -> Switching function C 3 -> Switching function D 4 -> Switching function E 5 -> Switching function F Pressure [1.0E-11, 9.9E+3] Output: DevVoid |
Set setpoint upper threshold |
ReadUpperThresholdInput: DevShort Setpoint 0 -> Switching function A 1 -> Switching function B 2 -> Switching function C 3 -> Switching function D 4 -> Switching function E 5 -> Switching function F Output: DevDouble Pressure |
Get setpoint upper threshold |
ReadSensorSourceInput: DevShort Setpoint 0 -> Switching function A 1 -> Switching function B 2 -> Switching function C 3 -> Switching function D 4 -> Switching function E 5 -> Switching function F Output: DevShort Source 0 -> Measuring circuit 0 1 -> Measuring circuit 1 2 -> Measuring circuit 2 3 -> Measuring circuit 3 4 -> Measuring circuit 4 5 -> Measuring circuit 5 |
Get setpoint source |
WriteSensorSourceInput: DevVarShortArray Setpoint, Source Setpoint 0 -> Switching function A 1 -> Switching function B 2 -> Switching function C 3 -> Switching function D 4 -> Switching function E 5 -> Switching function F Source: 0 -> Measuring circuit 0 1 -> Measuring circuit 1 2 -> Measuring circuit 2 3 -> Measuring circuit 3 4 -> Measuring circuit 4 5 -> Measuring circuit 5 Output: DevVoid |
Set setpoint switching function |
RegisterNameInput: DevVarLongStringArray Channel, Name Channel [0,5] Name max 64 characters Output: DevVoid |
Set channel name |
UnregisterNameInput: DevShort Channel [0,5] Output: DevVoid |
Unregister channel name |
Pipes:
Properties:
Name | Description |
---|---|
SerialDeviceDevString | — |
TimeoutDevULong | Milliseconds |
ThreadSleepDevULong | Millisecond |
ProxySleepDevULong | Millisecond |
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.
3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.