This is historical information of device classes implemented in ThermocoupleioLogikE2262 device server.

Use this link to find the valid information.

Development status: Released
Information status: New

Contact:



Class Description


Server for controlling the thermocouple ioLogikE2262

Families: Instrumentation

Key words:

Platform: Unix Like

Language: Cpp

License:

Contact:

Hardware


Manufacturer: Moxa

Product:

ioLogikE2262

Bus: Ethernet

Class interface


Attributes:

Name Description
Enable_00Scalar: DevLong
Enable_01Scalar: DevLong
Enable_02Scalar: DevLong
Enable_03Scalar: DevLong
Enable_04Scalar: DevLong
Enable_05Scalar: DevLong
Enable_06Scalar: DevLong
Enable_07Scalar: DevLong
Stype_00Scalar: DevLong
Stype_01Scalar: DevLong
Stype_02Scalar: DevLong
Stype_03Scalar: DevLong
Stype_04Scalar: DevLong
Stype_05Scalar: DevLong
Stype_06Scalar: DevLong
Stype_07Scalar: DevLong
Utype_00Scalar: DevLong
Utype_01Scalar: DevLong
Utype_02Scalar: DevLong
Utype_03Scalar: DevLong
Utype_04Scalar: DevLong
Utype_05Scalar: DevLong
Utype_06Scalar: DevLong
Utype_07Scalar: DevLong
CStatus_00Scalar: DevDouble Measured value in physical units
CStatus_01Scalar: DevDouble Measured value in physical units
CStatus_02Scalar: DevDouble Measured value in physical units
CStatus_03Scalar: DevDouble Measured value in physical units
CStatus_04Scalar: DevDouble Measured value in physical units
CStatus_05Scalar: DevDouble Measured value in physical units
CStatus_06Scalar: DevDouble Measured value in physical units
CStatus_07Scalar: DevDouble Measured value in physical units

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.

Pipes:

Properties:

Name Description
IpAddressDevString Ip Address (ex. haspp04t11.desy.de)

23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.



3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:19 Jan 2017, 10:55 a.m.