This is historical information of device classes implemented in Danfysik_9100 device server.
Use this link to find the valid information.
Development status:
New development
Information status: Updated
Contact:
Class Description
This device has been developed to prepare a testbench for Danfysik 9100 device server.
Families: Simulators
Key words:
Platform: All Platforms
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
Name | Description |
---|---|
SimulateSerialFailScalar: DevBoolean | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
DevSerFlushInput: DevLong flush to do 0=input 1=output 2=both Output: DevVoid |
— |
DevSerreadRawInput: DevVoid Output: DevString pointer to the string read updated |
— |
DevSerWriteStringInput: DevString String to write Output: DevLong Number of characters written |
— |
Pipes:
Properties:
Class Description
The tailor is rich and my mother is in the kitchen.
Families: PowerSupply
Key words:
Platform: All Platforms
Language: Python
Contact:
Hardware
Manufacturer: Danfysic
Product:
9100
Bus: Not Applicable
Class interface
Attributes:
Name | Description |
---|---|
CurrentScalar: DevDouble | — |
CurrentSetpointScalar: DevDouble | — |
VoltageScalar: DevDouble | — |
CurrentSlewrateScalar: DevDouble | — |
AmbientTemperatureScalar: DevDouble | — |
StateCode64Scalar: DevLong64 | — |
RemoteModeScalar: DevBoolean | — |
ErrorsSpectrum: DevString | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
OffInput: DevVoid Output: DevVoid |
— |
OnInput: DevVoid Output: DevVoid |
— |
ResetInterlocksInput: DevVoid Output: DevVoid |
— |
UpdateStatusInput: DevVoid Output: DevVoid |
— |
ReadADInput: DevShort Output: DevString |
— |
Pipes:
Properties:
Name | Description |
---|---|
SerialLineDevString | The serial line to be used |
Updated:
A device class has been added.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.
3 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.