This is historical information of device classes implemented in XMCD device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
Computes a current for normalization using the PiLC.
Families: Miscellaneous
Key words:
Platform: Unix Like
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: DESY
Product:
PiLC
Bus: Not Applicable
Class interface
Attributes:
Name | Description |
---|---|
IpImDiffScalar: DevDouble | Iplus - Iminus |
ClockTimeScalar: DevDouble | — |
IntensityScalar: DevDouble | — |
IPlusScalar: DevDouble | ItPlus/I0Plus |
IMinusScalar: DevDouble | ItMinus/I0Minus |
ItPlusScalar: DevLong | — |
I0PlusScalar: DevLong | — |
ItMinusScalar: DevLong | — |
I0MinusScalar: DevLong | — |
GateStatusScalar: DevLong | — |
MirrorDelay1Scalar: DevFloat | Reads last written value. The write value is rounded to multiples of 5 ns. |
MirrorDelay2Scalar: DevFloat | Reads last written value. The write value is rounded to multiples of 5 ns. |
ClockCounterScalar: DevDouble | — |
I0Plus1Scalar: DevLong | — |
I0Plus2Scalar: DevLong | — |
I0Minus1Scalar: DevLong | — |
I0Minus2Scalar: DevLong | — |
TGAFrequencyScalar: DevDouble | Frequency of the PGA. Used to convert PiLC counts to time. |
IpImXasScalar: DevDouble | - Iplus - Iminus |
ItPlus2Scalar: DevLong | — |
ItMinus2Scalar: DevLong | — |
ModeScalar: DevLong | Mode for Iplus and Iminus calculation: 0 -> absortion, 1 -> fluorescence/diffraction |
ModeInfoScalar: DevString | Shows selected mode in Mode attribute. |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
Pipes:
Properties:
Name | Description |
---|---|
PiLCDeviceDevString | Name of the PiLCDevice connecting to the hw. |
InitPiLCAtStartDevLong | If set to 1, the PiLC is initilized when the server is started. |
Updated:
The device class has been updated.
You can see previous version here .
13 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
26 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
25 Aug 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.