Development status:
Released,
Release: Release_1_0
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/BeamlineComponents/Mirrors/MirrorCalculator
Contact:
gerd.wellenreuther@desy.de
Class Description
Families: Miscellaneous
Key words:
Platform: All Platforms
Language: Python
Contact: gerd.wellenreuther@desy.de
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
Name | Description |
---|---|
Mir1Hor_PositionScalar: DevDouble | — |
Mir2Hor_PositionScalar: DevDouble | — |
Mir1Rot_PositionScalar: DevDouble | — |
Mir2Rot_PositionScalar: DevDouble | — |
Mirz_PositionScalar: DevFloat | — |
Mir1Hor_OffsetScalar: DevDouble | — |
Mir2Hor_OffsetScalar: DevDouble | — |
Mir1Rot_OffsetScalar: DevDouble | — |
Mir2Rot_OffsetScalar: DevDouble | — |
Mirz_OffsetScalar: DevFloat | — |
Mir1Hor_ConversionScalar: DevDouble | — |
Mir2Hor_ConversionScalar: DevDouble | — |
Mir1Rot_ConversionScalar: DevDouble | — |
Mir2Rot_ConversionScalar: DevDouble | — |
Mirz_ConversionScalar: DevFloat | — |
LmirrorsScalar: DevDouble | — |
dStripeScalar: DevDouble | — |
dM1M2Scalar: DevDouble | — |
Incident_beam_angleScalar: DevDouble | — |
Incident_beam_offsetScalar: DevDouble | — |
Exiting_beam_angleScalar: DevFloat | — |
Exiting_beam_offsetScalar: DevFloat | — |
Intermediate_beam_angleScalar: DevFloat | — |
Intermediate_beam_offsetScalar: DevFloat | — |
M1_E_criticalScalar: DevDouble | — |
M2_E_criticalScalar: DevDouble | — |
M1_pos_percScalar: DevDouble | — |
M2_pos_percScalar: DevDouble | — |
Stripe_coatingScalar: DevString | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
Pipes:
Properties:
Name | Description |
---|---|
Mir1Hor_devnameDevString | The Tango device name of the 1st horizontal mirror translation. |
Mir2Hor_devnameDevString | The Tango device name of the 2nd horizontal mirror tranlation. |
Mir1Rot_devnameDevString | The Tango device name of the 1st horizontal mirror rotation. |
Mir2Rot_devnameDevString | The Tango device name of the 2nd horizontal mirror rotation. |
Mirz_devnameDevString | The Tango device name of the mirror joint z-tranlation. |
Si_coating_filenameDevString | The full path to the file for the calculation of the Si-coated part of the mirror. |
Cr_coating_filenameDevString | The full path to the file for the calculation of the Cr-coated part of the mirror. |
Pt_coating_filenameDevString | The full path to the file for the calculation of the Pt-coated part of the mirror. |
Please log in to comment.