This is historical information of device classes implemented in Vibrations device server.

Use this link to find the valid information.

Development status: Released
Information status: New

Contact:



Class Description


Class computing vibrations in Petra Hall.

Families: Miscellaneous

Key words:

Platform: Unix Like

Language: Python

License:

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
MaxFreqScalar: DevFloat
DeviceScalar: DevString
DataTypeScalar: DevString
SampleRateScalar: DevFloat
TimeOffsetScalar: DevFloat
OversamplingScalar: DevFloat
AmpGainScalar: DevFloat
VTransmissionScalar: DevFloat
MinFreqScalar: DevFloat
DeviceTypeScalar: DevString
NDataPointsScalar: DevLong
TSampleScalar: DevFloat
NDataPointsSampleScalar: DevLong
NAverageScalar: DevFloat
VMeanScalar: DevFloat
VStdScalar: DevFloat
RMS1HzScalar: DevDouble
RMS2HzScalar: DevDouble
RMS5HzScalar: DevDouble
RMS10HzScalar: DevDouble
RMS20HzScalar: DevDouble
RMS50HzScalar: DevDouble
TimeAverageScalar: DevDouble
SumPSDsScalar: DevDouble
MaxSigScalar: DevDouble
MinSigScalar: DevDouble
Time0Scalar: DevString
LocalTimeScalar: DevString
CurrentFileNameScalar: DevString
TimeAxisSpectrum: DevDouble
FrequenciesSpectrum: DevDouble
FrequenciesSampleSpectrum: DevDouble
SSpectrum: DevDouble
VSpectrum: DevDouble
ASpectrum: DevDouble
FftSSpectrum: DevDouble
FftVSpectrum: DevDouble
FftASpectrum: DevDouble
PSDSSpectrum: DevDouble
PSDVSpectrum: DevDouble
PSDASpectrum: DevDouble
RMSSSpectrum: DevDouble

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.

Pipes:

Properties:

Name Description
FilesPathDevString Path to the directory containing the data from Device.
DeviceDirectionDevString Identify the direction of the device in the room: nord (S1n), east (S1e) or z (S1z).

16 Nov 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:19 Jan 2017, 10:51 a.m.