Class Description
Class for the histograming module for the 8715/8710 ADCs of Canberra.
Families: Acquisition
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: VME
Class interface
Attributes:
Name | Description |
---|---|
DataLengthScalar: DevLong | Length of the data spectrum to be read from memory |
BankIdScalar: DevLong | Selects bank 0 or 1 from the MCA memory |
StateBank0Scalar: DevLong | 0 -> on\n1 -> running |
StateBank1Scalar: DevLong | 0 -> on\n1 -> running |
NbRoIsScalar: DevLong | — |
Counts1Scalar: DevDouble | — |
Counts2Scalar: DevDouble | — |
Counts3Scalar: DevDouble | — |
Counts4Scalar: DevDouble | — |
FlagReadScalar: DevLong | 1 if Read performed after Start |
Counts1DiffScalar: DevDouble | — |
Counts2DiffScalar: DevDouble | — |
Counts3DiffScalar: DevDouble | — |
Counts4DiffScalar: DevDouble | — |
DataSpectrum: DevLong | — |
CountsSpectrum: DevDouble | — |
CountsDiffSpectrum: DevDouble | Differential counts |
RoIsImage: DevLong | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
StartInput: DevVoid Output: DevLong Completion status |
Start MCA |
StopInput: DevVoid Output: DevLong Completion status |
Stop MCA |
ReadInput: DevVoid Output: DevLong Completion status |
Reads the VME MCA board (memory bank BankId) |
ClearInput: DevVoid Output: DevLong Completion status |
Clears the MCA bank BankId |
TakeCountsReferenceInput: DevVoid Output: DevVoid |
Take current counts for start computing the CountsDiff values. |
Pipes:
Properties:
Name | Description |
---|---|
VmeCardDevULong | selects the VME card, can be 0 or 1, def.: 0 |
BaseDevULong | VME base address. Default value 0x7000 (28672 in decimal) |
ChannelDevULong | Channel number |
MaxDataLengthDevLong | Maimum number of channels in the data spectrum |
Base2DevULong | VME A24/A32 address. Default: 0xd00000 (A24) (in decimal 13631488) |
SimulationModeDevULong | 0 real mode, 1 simulation mode |
Please log in to comment.
Generated
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.