Development status:
New development
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/BeamDiagnostics/EsrfBeamOptic/SoftXDipoleOptic
Contact:
Class Description
The aim of this class is to simplify beam emittance computation done in the beam emittance measurement system. This class compute some bean optics parameters inside ESRF dipole. This class is named SoftXDipoleOptic due to the two differents kind of ESRF dipole. This class is for dipole with the low magnetic field part at the dipole entrance (on the electron path)
Families: Calculation
Key words:
Platform: All Platforms
Language: Cpp
License: GPL
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
Name | Description |
---|---|
X_Alpha_0Scalar: DevDouble | Beta matrix alpha value at dipole entrance (X plane) |
X_Beta_0Scalar: DevDouble | Beta matrix beta value at dipole entrance (X plane) |
X_Eta_0Scalar: DevDouble | Dispersion function value at dipole entrance (X plane) |
X_Etap_0Scalar: DevDouble | Dispersion function derivate value at dipole entrance (X plane) |
X_AlphaScalar: DevDouble | Beta matrix inside alpha value at dipole at position Position (X plane) |
X_BetaScalar: DevDouble | Beta matrix beta value inside dipole at position Position (X plane) |
X_EtaScalar: DevDouble | Dispersion function value inside dipole at position Position (X plane) |
X_EtapScalar: DevDouble | Dispersion function derivative value inside dipole at position Position (X plane) |
Z_Alpha_0Scalar: DevDouble | Beta matrix alpha value at dipole entrance (Z plane) |
Z_Beta_0Scalar: DevDouble | Beta matrix beta value at dipole entrance (Z plane) |
Z_Eta_0Scalar: DevDouble | Dispersion function value at dipole entrance (Z plane) |
Z_Etap_0Scalar: DevDouble | Dispersion function derivative value at dipole entrance (Z plane) |
Z_AlphaScalar: DevDouble | Beta matrix alpha value inside dipole at position Position (Z plane) |
Z_BetaScalar: DevDouble | Beta matrix beta value inside dipole at position Position (Z plane) |
Z_EtaScalar: DevDouble | Dispersion function value inside dipole at position Position (Z plane) |
Z_EtapScalar: DevDouble | Dispersion function derivative value inside dipole at position Position (Z plane) |
PositionScalar: DevDouble | Position inside dipole. 0 is the optic element entrance |
EnergySpreadScalar: DevDouble | Particules beam energy spread. |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
Pipes:
Properties:
Name | Description |
---|---|
CstParDeviceNameDevString | — |
RDevDouble | Radius of curvature of the trajectory induced by dipole |
SoftRDevDouble | Radius of curvature of the trajectory induced by dipole in its low magnetic field section |
SoftLengthDevDouble | Length of the low magnetic field part of the ESRF dipole |
Please log in to comment.