Development status:
New development
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/BeamDiagnostics/EsrfBeamOptic/HardXDipoleOptic
Contact:
Class Description
The aim of this class is to simplify beam emittance computation done in the beam emittance measurement system. This class compute some bean optics parameters inside ESRF dipole. This class is named HardXDipoleOptic due to the two differents kind of ESRF dipole. This class is for dipole with the low magnetic field part at the dipole output (on the electron path)
Families: Calculation
Key words:
Platform: All Platforms
Language: Cpp
License: GPL
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
Name | Description |
---|---|
X_Alpha_0Scalar: DevDouble | Beta matrix alpha value at dipole entrance (X plane) |
X_Beta_0Scalar: DevDouble | Beta matrix beta value at dipole entrance (X plane) |
X_Eta_0Scalar: DevDouble | Dispersion function value at dipole entrance (X plane) |
X_Etap_0Scalar: DevDouble | Dispersion function derivative value at dipole entrance (X plane) |
X_AlphaScalar: DevDouble | Beta matrix alpha value inside dipole at a position Position (X plane) |
X_BetaScalar: DevDouble | Beta matrix beta value inside dipole at a position Position (X plane) |
X_EtaScalar: DevDouble | Dispersion function value inside dipole at position Position (X plane) |
X_EtapScalar: DevDouble | Dispersion function derivate value inside dipole at position Position (X plane) |
Z_Alpha_0Scalar: DevDouble | Beta matrix alplah value at dipole entrance (Z plane) |
Z_Beta_0Scalar: DevDouble | Beta matrix beta value at dipole entrance (Z plane) |
Z_Eta_0Scalar: DevDouble | Dispersion function value at dipole entrance (Z plane) |
Z_Etap_0Scalar: DevDouble | Dispersion function derivative value at dipole entrance (Z plane) |
Z_AlphaScalar: DevDouble | Beta matrix alpha value inside dipole at position Position (Z plane) |
Z_BetaScalar: DevDouble | Beta matrix beta value inside dipole at position Position (Z plane) |
Z_EtaScalar: DevDouble | Dispersion function value inside dipole at position Position (Z plane) |
Z_EtapScalar: DevDouble | Dispersion function derivative value inside dipole position Position (Z plane) |
PositionScalar: DevDouble | Position inside the dipole. 0 is the optic element entrance |
EnergySpreadScalar: DevDouble | Particules beam energy spread. |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
Pipes:
Properties:
Name | Description |
---|---|
CstParDeviceNameDevString | Constant parameter device name |
RDevDouble | Radius of curvature of the trajectory induced by dipole |
Please log in to comment.