This is historical information of device classes implemented in Cpci1150 device server.

Use this link to find the valid information.

Development status: New development
Information status: New

Contact:



Class Description


Families: Miscellaneous

Key words:

Platform: All Platforms

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: ADAS

Product:

CPCI 1150

Bus: Compact PCI

Class interface


Attributes:

Name Description
spectrum_acqX_ChaYSpectrum: DevFloat

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartInput: DevVoid
Output: DevVoid
Start acquisition
StopInput: DevVoid
Output: DevVoid
Stop acquisition
ResetInput: DevVoid
Output: DevVoid
Reset the board
GlobalReadInput: DevVoid
Output: DevVoid
Lauch an acquisition. Only available in SCAN mode.
GetBufferInput: DevVoid
Output: DevVoid
Get the buffer with the read values Only available in PCI mode.
ResetCounterInput: DevVoid
Output: DevVoid
Reset the count of interrupts. Only available in SYN and PCI mode

Pipes:

Properties:

Name Description
OversamplingDevUShort Define the oversampling value. Must be 0, 2, 4, 8 or 16
ConfigPatternArray of DevString Configuration of the channel pattern. First parameter of each string is the channel to configure. Second parameter is the etxremum value for the voltage scale of the configured channel. Must be `10V`, `5V`, `2.5V` or `1.25V`.
ModeDevString Define the general mode. Must be `SCAN`, `SYN` or `PCI`
TriggerDevString Define the signal used to trigger the acquisitions. Required for SYN and PCI mode. Must be `Timer`, `LEMO`, or `PXI`
SampleRateDevUShort Default frequency of the timer. Required for SCAN mode and Timer trigger. The maximum value depends on both resolution and oversampling. See the table.
ResolutionDevString Number of bits for the sample. Increasing resolution lowers the maximum sample rate. Must be `12bits`, `14bits` or `16bits`
PolarityDevString Define the polarity of the channel. Use `Uni` for single-wire use. Use `Dif` for differential use.
FormatArray of DevString Define the format of the output data file. Required for STREAM mode. Use `CSV` or `HDF5`.
BasenameArray of DevString Define the basename of the output data file. Required for STREAM mode. Use only `-`, `_` and alphanumeric characters The actual file name is completed with date, time and extention.

23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:19 Jan 2017, 10:40 a.m.