This is historical information of device classes implemented in MeasuredFillingPattern device server.

Use this link to find the valid information.

Development status: New development
Information status: Updated

Contact:



Class Description


Device to ...

Families: Calculation

Key words:

Platform: All Platforms

Language: Python

License:

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
FilledBunchesScalar: DevShort
OffsetHScalar: DevDouble Oscilloscope Horizontal Offset
OffsetH_expertScalar: DevDouble Oscilloscope Horizontal Offset
ScaleHScalar: DevDouble Oscilloscope Horizontal Scale
ScaleH_expertScalar: DevDouble Oscilloscope Horizontal Scale
SpuriousBunchesScalar: DevShort
StartingPointScalar: DevShort
StartingPoint_expertScalar: DevShort
ThresholdScalar: DevDouble
Threshold_expertScalar: DevDouble
TimingTriggerScalar: DevShort
TimingTrigger_expertScalar: DevShort
emitCyclicBufferScalar: DevBoolean This boolean attribute is to allow or not to emit the events on the cyclic Buffer. This is because it can cause delay dou to be too big buffer
nAcquisitionsScalar: DevUShort Number of elements in the cyclic buffer from where the calculation takes the data.
nBunchesScalar: DevShort
resultingFrequencyScalar: DevDouble Expert attribute to read the frequency with this device is pushing results in the output
CurrentSampleRateScalar: DevDouble
BunchIntensitySpectrum: DevDouble
CyclicBufferTraceSpectrum: DevString Internal use attribute to have information about how the buffer changes
InputSignalSpectrum: DevDouble
cyclicBufferImage: DevDouble Expert attribute to be able to check the cyclic buffer evolution

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartInput: DevVoid
Output: DevVoid
StopInput: DevVoid
Output: DevVoid
ExecInput: DevString
statement to executed
Output: DevString
result

Pipes:

Properties:

Name Description
AutoStartDevBoolean Configure if the device must start the calculation by default when it is launched
FCTAttributeDevString Channel of the scope from where the readings are get
RfGeneratorAttrDevString RfGenerator Attr name from where the frequency is read from time to time
RfGeneratorDevDevString RfGenerator Device name from where the frequency is read from time to time
dcctAttrDevString DCCT Attr name from where the sr current is read from time to time
dcctDevDevString DCCT Device name from where the sr current is read from time to time
erDevDevString Event Receiver Device name
scoDevDevString Scope Device name where one channel has the FCT signal

Class Description


Device to ...

Families: Calculation

Key words:

Platform: All Platforms

Language: Python

License:

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
ThresholdScalar: DevUShort
Threshold_expertScalar: DevUShort
resultingFrequencyScalar: DevDouble Expert attribute to read the frequency with this device is pushing results in the output
nBunchesScalar: DevShort
SpuriousBunchesScalar: DevShort
FilledBunchesScalar: DevShort
nAcquisitionsScalar: DevUShort Number of elements in the cyclic buffer from where the calculation takes the data.
BunchIntensitySpectrum: DevDouble
InputSignalSpectrum: DevDouble

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartInput: DevVoid
Output: DevVoid
StopInput: DevVoid
Output: DevVoid
ExecInput: DevString
statement to executed
Output: DevString
result

Pipes:

Properties:

Name Description
PhCtDevDevString Photon Counter device name
AutoStartDevBoolean Configure if the device must start the calculation by default when it is launched
PhCtAttrDevString Photon Counter histogram property name
dcctAttrDevString DCCT Attr name from where the sr current is read from time to time
dcctDevDevString DCCT Device name from where the sr current is read from time to time

23 Feb 2017, Piotr Goryl
Updated:
A device class has been added.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



3 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:19 Jan 2017, 10:37 a.m.