This is historical information of device classes implemented in Agilent33500B device server.

Use this link to find the valid information.

Development status: New development
Information status: Updated

Contact:



Class Description


A class to control the Agilent 33500B waveform generator

Families: OtherInstruments

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: none

Bus: Ethernet

Class interface


Attributes:

Name Description
ImpedanceScalar: DevDouble
AmplitudeScalar: DevDouble
OffsetScalar: DevDouble
SampleRateScalar: DevDouble
TriggerModeScalar: DevShort
TriggeringScalar: DevShort
DelayScalar: DevDouble
TrackModeScalar: DevShort
BurstModeScalar: DevShort
BurstCycleScalar: DevShort
BurstStateScalar: DevShort
HighVoltageScalar: DevDouble
LowVoltageScalar: DevDouble
Configuration_FileScalar: DevString
FunctionScalar: DevShort
FrequencyScalar: DevDouble
NoiseBandwidthScalar: DevDouble
OutputModeScalar: DevShort 0=> Normal 1=> Gated (output activated by an external input)
WaveformFilterScalar: DevShort 0=>Normal 1=>Step 2=>OFF
WaveformSpectrum: DevDouble

Commands:

Name Description
ResetInput: DevVoid
Output: DevVoid
Reset the generator
OnInput: DevVoid
Output: DevVoid
Switch ON the output
OffInput: DevVoid
Output: DevVoid
Switch off the output
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
GetConfigurationFilePathInput: DevVoid
Output: DevString
Configuration file path
Returns the absolute confiration file path
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
LoadConfigurationFileInput: DevString
Configuration file name (without the path)
Output: DevVoid
Loads a configuration file
SaveConfigurationFileInput: DevString
Configuration file name (without the path)
Output: DevVoid
Save a configuration file
SaveToFlashInput: DevVoid
Output: DevVoid
Save device configuration flash memory (block 0 used when booting)

Pipes:

Properties:

Name Description
IPAddressDevString
OutputDevShort Output number (Start from 1)
TimeoutDevLong Communication timeout (millisec)
WaveformFileDevString Name of the file where the waveform is stored
ConfigFilePathDevString Absolute path were config file are stored
ConfigFileDevString Configuration file
TrackModeSupportDevBoolean true if Track mode is supported
SaveInternalConfigDevBoolean Save settings (if true) to internal reboot memory after each parameter change.

29 Jan 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Jan 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



15 Jan 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



8 Jan 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



1 Jan 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Dec 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Dec 2021, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



11 Dec 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Dec 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



6 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



9 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



2 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



11 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



28 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



21 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



14 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



7 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



31 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



24 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



17 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



10 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



3 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



26 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



19 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



12 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



5 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



29 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



15 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



8 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



1 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



24 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



17 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



10 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



3 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



6 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Feb 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Feb 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Feb 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



6 Feb 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



11 Nov 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



5 Aug 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:18 Dec 2021, 3:32 a.m.