This is historical information of device classes implemented in PiLCShutterControlP10 device server.
Use this link to find the valid information.
Development status:
New development
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/OtherInstruments/PiLCShutterControlP10
Contact:
Class Description
Shutter Control at p10 via PiLC
Families: OtherInstruments
Key words:
Platform: Unix Like
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
Name | Description |
---|---|
ActiveScalar: DevLong | — |
ExposureScalar: DevDouble | — |
DelayScalar: DevDouble | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
Pipes:
Properties:
Name | Description |
---|---|
PiLCDeviceDevString | Name of the PiLC Tango Device to connect to |
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.