This is historical information of device classes implemented in OwisMMS19 device server.
Use this link to find the valid information.
Development status:
New development
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Motion/MotorControllers/OwisMMS19
Contact:
Class Description
Controlling MMS19 actuactors from Owis
Families: Motion
Key words:
Platform: Unix Like
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: Owis
Product:
MMS19
Bus: Not Applicable
Class interface
Attributes:
Name | Description |
---|---|
PositionScalar: DevDouble | Motor position in physical units. Writing will move the motor. |
UnitLimitMinScalar: DevDouble | Software minimum limit (physical units) |
UnitLimitMaxScalar: DevDouble | Software maximum limit (physical units) |
SlewRateScalar: DevDouble | Motor velocity (physical units/s) |
AccelerationScalar: DevDouble | Motor acceleration (physical units/s^2) |
JerkScalar: DevDouble | Motor Jerk (movement parameter) |
CwLimitScalar: DevLong | 1 if positive limit is reached. |
CcwLimitScalar: DevLong | 1 if negative limit is reached. |
TargetPositionScalar: DevDouble | Position set (physical units) |
CurrentSlewRateScalar: DevDouble | Current motor velocity (physical units/s) |
PositiveScalar: DevLong | Enable/disable positive movement |
EnableScalar: DevLong | Enable/disable axis |
NegativeScalar: DevLong | Enable/disable negative movement |
OverrideScalar: DevLong | Override value |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
CalibrateInput: DevDouble Position to calibrate to Output: DevVoid |
Set current position to the value given as argument. |
ResetInput: DevVoid Output: DevVoid |
— |
HomeInput: DevVoid Output: DevVoid |
Set position to 0 using limit switch |
StopMoveInput: DevVoid Output: DevVoid |
Stop motor |
Pipes:
Properties:
Name | Description |
---|---|
AdsDeviceDevString | Ads Tango Device talking to the controller. |
AxisNbDevLong | Axis Id: starting from 1. |
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.