This is historical information of device classes implemented in AnalyzerEP01 device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
- Changes the energy of the analyzer detector system as a combined
- movement of three motors.
Families: Motion
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
Name | Description |
---|---|
CrystalSpacingScalar: DevDouble | Analyzer crystal spacing. |
RowlandScalar: DevDouble | Rowland circle radius |
FakeNumberScalar: DevDouble | Parameter that can vary for keeping analyzer and detector angles in sync. |
PositionScalar: DevDouble | Analyzer Energy |
UnitLimitMaxScalar: DevDouble | — |
UnitLimitMinScalar: DevDouble | — |
PositionSimScalar: DevDouble | — |
ResultSimSpectrum: DevString | Show the motor positions for the energy written in PositionSim |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
CalibrateInput: DevDouble Value to be calibrated Output: DevVoid |
— |
StopMoveInput: DevVoid Output: DevVoid |
Stop the three motors. |
Pipes:
Properties:
Name | Description |
---|---|
AnalyzerThetaDevString | Name of the analyzer_theta Tango device |
AnalyzerZDevString | Name of the analyzer_z Tango device. |
DetThetaDevString | Name of the det_theta Tango device. |
DetYDevString | Name of the det_y Tango device. |
DetZDevString | Name of the det_z Tango device. |
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2
on:19 Jan 2017, 10:35 a.m.