This is historical information of device classes implemented in LKS336TempCtrl device server.
Use this link to find the valid information.
Development status:
Released
Information status: Updated
Contact:
maria-teresa.nunez-pardo-de-vera@desy.de
Class Description
Class for controlling the Lake Shore Model 336 Temperature Controller
Families: Instrumentation
Key words:
Platform: All Platforms
Language: Cpp
Contact: maria-teresa.nunez-pardo-de-vera@desy.de
Hardware
Manufacturer: none
Bus: GPIB
Class interface
Attributes:
Name | Description |
---|---|
OutputChannelAScalar: DevDouble | — |
SensorTypeAScalar: DevLong | Sensor Type: 0->disabled,1->Diode,2->Platinum RTD,3->NTC RTD,4->Thermocouple |
SensorTypeAInfoScalar: DevString | — |
InputCurveAScalar: DevLong | Input Curve for channel A. |
TlimitAScalar: DevLong | A temperature limit in Kelvin for which to shutdown all control outputs when exceeded. 0-> turns this feature off. |
OutputChannelBScalar: DevDouble | — |
SensorTypeBScalar: DevLong | Sensor Type: 0->disabled,1->Diode,2->Platinum RTD,3->NTC RTD,4->Thermocouple |
SensorTypeBInfoScalar: DevString | — |
InputCurveBScalar: DevLong | Input Curve for channel B. |
TlimitBScalar: DevLong | A temperature limit in Kelvin for which to shutdown all control outputs when exceeded. 0-> turns this feature off. |
OutputChannelCScalar: DevDouble | — |
SensorTypeCScalar: DevLong | Sensor Type: 0->disabled,1->Diode,2->Platinum RTD,3->NTC RTD,4->Thermocouple |
SensorTypeCInfoScalar: DevString | — |
InputCurveCScalar: DevLong | Input Curve for channel C, |
TlimitCScalar: DevLong | A temperature limit in Kelvin for which to shutdown all control outputs when exceeded. 0-> turns this feature off. |
OutputChannelDScalar: DevDouble | — |
SensorTypeDScalar: DevLong | Sensor Type: 0->disabled,1->Diode,2->Platinum RTD,3->NTC RTD,4->Thermocouple |
SensorTypeDInfoScalar: DevString | — |
InputCurveDScalar: DevLong | Input Curve for channel D, |
TlimitDScalar: DevLong | A temperature limit in Kelvin for which to shutdown all control outputs when exceeded. 0-> turns this feature off. |
ResistanceH1Scalar: DevLong | 1->25Ohms, 2->50Ohms |
ControlModeH1Scalar: DevLong | 0= Off 1= Close loop PID 2= Zone 3= Open loop 4= Monitor out 5= Warmup supply |
ControlModeH1InfoScalar: DevString | — |
ControlChannelH1Scalar: DevLong | 0->none,1->A,2->B,3->C,4->D |
ProportionalH1Scalar: DevFloat | Proportional parameter (also called gain). |
IntegralH1Scalar: DevFloat | Integral parameter (also called reset). |
DerivativeH1Scalar: DevLong | Derivative parameter (also called rate). |
SetPointH1Scalar: DevDouble | Temperature Setpoint |
RampRateH1Scalar: DevDouble | — |
HeaterRangeH1Scalar: DevLong | Heater Range: 0 to 5. |
ControlModeH2Scalar: DevLong | 0= Off 1= Close loop PID 2= Zone 3= Open loop 4= Monitor out 5= Warmup supply |
ControlModeH2InfoScalar: DevString | — |
ControlChannelH2Scalar: DevLong | 0->none,1->A,2->B,3->C,4->D |
ProportionalH2Scalar: DevFloat | Proportional parameter (also called gain). |
IntegralH2Scalar: DevFloat | Integral parameter (also called reset). |
DerivativeH2Scalar: DevLong | Derivative parameter (also called rate). |
SetPointH2Scalar: DevDouble | Temperature Setpoint |
RampRateH2Scalar: DevDouble | — |
HeaterRangeH2Scalar: DevLong | Heater Range: 0 to 5. |
TmaxScalar: DevDouble | Attribute only to write and read. |
RampOffOnH1Scalar: DevLong | — |
RampOffOnH2Scalar: DevLong | — |
ResistanceH2Scalar: DevLong | 1->25Ohms, 2->50Ohms |
CurvesInfoSpectrum: DevString | Information about curves and the allowed sensor types and temperature ranges. |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
Pipes:
Properties:
Name | Description |
---|---|
ControlerDeviceDevString | Name of the controller device, can be a GpibDeviceServer SocketDevice Prologixadapter When using Prologixadapter, you will have to set the GpipID. |
GpibIDDevLong | Gpib device address when using a prologix adapter |
Updated:
The device class has been updated.
You can see previous version here .
6 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
30 Oct 2021, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
27 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created: