This is historical information of device classes implemented in CollisionsSensor device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
Check possible collisions before allowing the movement of a motor.
Families: Motion
Key words:
Platform: All Platforms
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
Name | Description |
---|---|
Value1Scalar: DevDouble | Receives and stores data from motors need in the check routine. |
Value2Scalar: DevDouble | Receives and stores data from motors need in the check routine. |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
CheckCollisionInput: DevVarDoubleStringArray Beamline identification (string), motor device name, new motor position Output: DevLong 0 -> allows movement, 1 -> movement not allowed |
Check if the movement to the new position for the given motor is possible without collisions. Returns 0 or 1 depending if the movement can or not be done. |
Pipes:
Properties:
Name | Description |
---|---|
P09DptransctransDevDouble | Maximum allowed distance between ptrans and ctrans |
P09VptransDevDouble | ptrans value for a different allowed distance between mu and nu. |
P09VctransDevDouble | ctrans value for a different allowed distance between mu and nu. |
P09DnumuDevDouble | nu-mu value has to be smaller. |
P09Dnumu1DevDouble | mu-nu smaller if ptrans bigger than p09vptrans |
P09Dnumu2DevDouble | mu-nu smaller if ptrans smaller than p09vptrans |
P09Dnumu3DevDouble | mu-nu smaller if ctrans bigger than p09vctrans |
P09Dnumu4DevDouble | mu-nu smaller if ctrans smaller than p09vctrans |
P09DdelthetaDevDouble | Degrees between del and theta motors |
P09DdiaztheightMaxDevDouble | Maximum difference between diaz and table height |
P09DdiaztheightMinDevDouble | Minimum difference between diaz and table height |
P09ThPhiLowerLimitDevDouble | thpos+phipos > P09ThPhiLowerLimit |
P09ThPhiUpperLimitDevDouble | thpos+phipos < P09ThPhiUpperLimit |
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2
on:19 Jan 2017, 10:35 a.m.