This is historical information of device classes implemented in UndulatorP04 device server.
Use this link to find the valid information.
Development status:
Released,
Release: Release_1_5
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/MagneticDevices/UndulatorP04
Contact:
Class Description
Executes virtual motor scripts
Families: MagneticDevices
Key words:
Platform: All Platforms
Language: Python
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
Name | Description |
---|---|
PositionScalar: DevDouble | — |
UnitLimitMinScalar: DevDouble | — |
UnitLimitMaxScalar: DevDouble | — |
EnergySimScalar: DevDouble | — |
ResultGapSimScalar: DevLong | — |
GapTargetScalar: DevLong | The gaptarget on the undulator. |
GapScalar: DevLong | The gap on the undulator. |
ShiftScalar: DevLong | Reads current shift. By writting the shift is moved to the given value. |
ShiftInMovementScalar: DevLong | 1 if shift is moving |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
CalibrateInput: DevDouble Output: DevLong |
|
StopMoveInput: DevVoid Output: DevVoid |
— |
ResetMotorInput: DevVoid Output: DevVoid |
Reset a hardware fault. |
StartMoveInput: DevVoid Output: DevVoid |
Start a gap or taper movement. |
Pipes:
Properties:
Name | Description |
---|---|
UndulatorCodeDevString | The complete path to the undulator code |
PTTGW_NameDevString | The name of the plc device for the undulator. |
LockTimeMsDevFloat | After sending a StartMove command, the state will be locked to MOVING for `LockTimeMs` milliseconds. This is to avoid state oscillations if the actual start of the move takes some time. |
Updated:
The device class has been updated.
You can see previous version here .
23 Oct 2021, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.