This is historical information of device classes implemented in K2Modulator2 device server.
Use this link to find the valid information.
Development status:
New development
Information status: Updated
Contact:
Class Description
This class is able to control a ScandiNova K2 modulator equipped with an ethernet interface.
Families: Controllers
Key words:
Platform: All Platforms
Language: Cpp
Contact:
Hardware
Manufacturer: ScandiNova Systems AB
Product:
K2
Bus: Socket
Class interface
Attributes:
Name | Description |
---|---|
SetFilCurrScalar: DevDouble | Set filament current.. |
CvdScalar: DevDouble | Capacitive Voltage Divider. Modulator output pulse voltage in KV units. |
CtScalar: DevDouble | Current Transformer. Modulator pulse output current. Unit ampere. |
PrfScalar: DevDouble | Pulse Repetion Frequency. |
PowerScalar: DevDouble | Modulator average output power. |
HvPsVoltageScalar: DevDouble | HV PS DC voltage output read value. The Primary voltage. |
FilamentVoltageScalar: DevDouble | — |
FilamentCurrentScalar: DevDouble | — |
BiasVoltageScalar: DevDouble | Pulse transformer bias voltage. |
BiasCurrentScalar: DevDouble | Pulse transformer bias current. |
SolenoidPs1VoltageScalar: DevDouble | Klystron solenoid PS1 voltage. |
SolenoidPs1CurrentScalar: DevDouble | Klystron solenoid PS1 current. |
SolenoidPs2VoltageScalar: DevDouble | Klystron solenoid PS2 voltage. |
SolenoidPs2CurrentScalar: DevDouble | Klystron solenoid PS2 current. |
SolenoidPs3VoltageScalar: DevDouble | Klystron solenoid PS3 voltage. |
SolenoidPs3CurrentScalar: DevDouble | Klystron solenoid PS3 current. |
SolenoidPs4VoltageScalar: DevDouble | Klystron solenoid PS4 voltage. |
SolenoidPs4CurrentScalar: DevDouble | Klystron solenoid PS4 current. |
SolenoidPs5VoltageScalar: DevDouble | Klystron solenoid PS5 voltage. |
SolenoidPs5CurrentScalar: DevDouble | Klystron solenoid PS5 current. |
SolenoidPs6VoltageScalar: DevDouble | Klystron solenoid PS6 voltage. |
SolenoidPs6CurrentScalar: DevDouble | Klystron solenoid PS6 current. |
RemainingTimeScalar: DevLong | Indicates the time in seconds before the requested modulator state is reached. e,g. when waiting for the filament preheat time period. |
ModStateReadScalar: DevUShort | Modulator StateRead variable, See Control System Manual. |
ModStateSetScalar: DevUShort | Modulator StateSet variable. See Control System Manual. |
SetHvVoltScalar: DevDouble | Set voltage for DCPS. |
AccessLevelScalar: DevShort | Actual acees level. -1 = LOCAL mode. Read access 2 = REMOTE mode. Full Write and Read access. |
SetPs1CurrentScalar: DevDouble | Set solenoid PS 1 current.. |
SetPs2CurrentScalar: DevDouble | Set Current solenoid PS 2.. |
SetPs3CurrentScalar: DevDouble | Set Current solenoid PS 3. |
SetPs4CurrentScalar: DevDouble | Set Current solenoid PS 4. |
SetPs5CurrentScalar: DevDouble | Set Current solenoid PS 5. |
SetPs6CurrentScalar: DevDouble | Set Current solenoid PS 6. |
SetBiasCurrScalar: DevDouble | Set bias current.. |
CommandStatusScalar: DevLong | Status for last command. 0 = OK. 1 = Not connected. 2 = Timeout. 3 = Range error. 4 = Access error. 5 = Parameter error. |
ComStatusScalar: DevLong | Communication status. 0 = OK. 1 = Not connected. |
PulsewidthScalar: DevDouble | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
ResetInput: DevVoid Output: DevVoid |
Reset active modulator interlocks. |
OffInput: DevVoid Output: DevVoid |
Request modulator OFF state. |
StandbyInput: DevVoid Output: DevVoid |
Request modulator STANDBY state. |
HVInput: DevVoid Output: DevVoid |
Request modulator HV state. |
TrigInput: DevVoid Output: DevVoid |
Request modulator TRIG state. |
ReadFloatVariableInput: DevLong Output: DevDouble |
Read a modulator variable (float). Input argument Variable ID. Returns variable value. |
SetIntVariableInput: DevVarLongArray Output: DevShort |
Set a modulator variable (Int). Input argument [Variable ID,Value,...]. Success returns zero.. |
SetCalibInput: DevVarDoubleArray Output: DevUShort |
Set calibraion (scaling) data for a Modulator variable. Input argument [Variable ID,calib data,...]. Success returns zero. |
ReadCalibInput: DevLong Output: DevVarDoubleArray |
Read calibraion (scaling) data for a Modulator variable. Input argument Variable ID. Returns calibration data. |
ReadIntArrayInput: DevLong Output: DevVarLongArray |
— |
ReadFloatArrayInput: DevLong Output: DevVarDoubleArray |
— |
ReadIntVariableInput: DevLong Output: DevLong |
— |
SetFloatVariableInput: DevVarDoubleArray Output: DevLong |
— |
Pipes:
Properties:
Name | Description |
---|---|
IPDevString | IP address |
Updated:
The device class has been updated.
You are looking at this version now.
12 Oct 2021, MAX-IV Device Classes
Updated:
The device class has been updated.
You can see previous version here .
12 Oct 2021, MAX-IV Device Classes
Updated:
The device class has been updated.
You can see previous version here .
12 Oct 2021, MAX-IV Device Classes
Updated:
The device class has been updated.
You can see previous version here .
12 Oct 2021, MAX-IV Device Classes
Updated:
The device class has been updated.
You can see previous version here .
12 Oct 2021, MAX-IV Device Classes
Created:
The device class has been added to catalogue.