This is historical information of device classes implemented in LKSf41Gaussmeter device server.
Use this link to find the valid information.
Development status:
New development
Information status: Updated
Contact:
Class Description
Lakeshore F41 Gaussmeter
Families: MeasureInstruments
Key words:
Platform: Unix Like
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: Lakeshore
Product:
F41
Bus: Data Socket
Class interface
Attributes:
Name | Description |
---|---|
FieldControlScalar: DevLong | — |
OpenLoopScalar: DevLong | 0 -> close loop 1 -> open loop |
MagneticFieldScalar: DevDouble | — |
PValueScalar: DevDouble | Closed loop P-Value |
IValueScalar: DevLong | Closed loop I-Value |
SetpointFieldScalar: DevDouble | — |
SetpointOpenLoopScalar: DevDouble | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
Pipes:
Properties:
Name | Description |
---|---|
SocketDeviceDevString | Name of the Tango Device making the socket connection |
RangeDevString | Range (AUTO if auto range) |
IntegrationTimeDevString | Integration time (DEF if default) |
MeasurementUnitDevString | — |
ModeDevString | — |
Updated:
The device class has been updated.
You can see previous version here .
7 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
31 Jul 2021, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
24 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
17 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
10 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
3 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
26 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
19 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
12 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
5 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
30 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
29 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
15 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
8 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
1 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
24 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
17 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
10 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
3 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
27 Mar 2021, DS Admin
Created:
The device class has been added to catalogue.