Class Description
SRS Current Preamplifier SR570
Families: MeasureInstruments
Key words:
Platform: Unix Like
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: Standord Research Systems
Product:
SR570
Bus: Serial Line
Class interface
Attributes:
Name | Description |
---|---|
SensitivityScalar: DevLong | — |
SensitivityCalModeScalar: DevLong | 0 -> cal 1 -> uncal |
SensitivityCalVernierScalar: DevLong | Percentage from full scale |
InputOffsetOffOnScalar: DevLong | 0 -> off 1 -> on |
InputOffsetLevelScalar: DevLong | — |
InputOffsetSignScalar: DevLong | 0 -> neg 1 -> pos |
InputOffsetCalModeScalar: DevLong | 0 -> cal 1 -> uncal |
InputOffsetCalVernierScalar: DevLong | 0 to +/-100% of full scale |
BiasOffOnScalar: DevLong | 0 -> off 1 -> on |
BiasLevelScalar: DevLong | — |
FilterTypeScalar: DevLong | 0 -> 6 dB highpass 1 -> 12 dB highpass 2 -> 6 dB bandpass 3 -> 6 dB lowpass 4 -> 12 dB lowpass 5 -> none |
LPFilterFreqScalar: DevLong | — |
HPFilterFreqScalar: DevLong | — |
GainModeScalar: DevLong | 0 Low Noise 1 High Bandwidth 2 Low Drift |
InvertScalar: DevLong | 0 non-inverted 1 inverted |
BlankScalar: DevLong | 0 no blank 1 blank |
SensitivityPhysicalScaleScalar: DevString | 0 1 2 - > 1 2 5 pA/V 3 4 5 -> 10 20 50 pA/V 6 7 8 -> 100 200 500 pA/V 9 10 11 -> 1 2 5 nA/V 12 13 14 -> 10 20 50 nA/V 15 16 17 -> 100 200 500 nA/V 18 19 20 -> 1 2 5 µA/V 21 22 23 -> 10 20 50 µA/V 24 25 26 ->100 200 500 µA/V 27 ->1 mA/V |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
ResetFilterInput: DevVoid Output: DevVoid |
resets filter capacitors to clear an overload condition |
ResetAllInput: DevVoid Output: DevVoid |
resets the amplifier to default settings |
Pipes:
Properties:
Name | Description |
---|---|
IPAddressDevString | IP Address in case the connection is done via Ethernet |
PortNbDevLong | Port number in case the connection is done via Ethernet |
SerialPortDevString | Serial port with the rs232 connection, e.g. /dev/ttyUSB0. |
Updated:
The device class has been updated.
You can see previous version here .
16 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
31 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
24 Jul 2021, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
17 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
10 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
3 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
26 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
19 Jun 2021, DS Admin
Created:
The device class has been added to catalogue.