Class Description


Maps the Dectris Eigers Simplon API modules to tango devices. All supported parameters are dynamically added as commands or attributes. Single parameters can be ignored or set to expert view level through device properties.

Families: Acquisition

Key words:

Platform: All Platforms

Language: Cpp

License: GPL

Contact: jan.meyer@desy.de

Hardware


Manufacturer: Dectris

Product:

Simplon API

Bus: TCP/UDP

Class interface


Attributes:

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.

Pipes:

Properties:

Name Description
HostDevString Hostname or IP address of the DCU where Simplon API is running on.
ModuleDevString Simplon module (``detector``, ``filewriter``, ``monitor``, ``stream``, ``system``) to map.
VersionDevString Simplon API version
IgnoreDevString Comma separated list of attributes (for example ``PixelMask``) or commands which should not be exported. Supports one asterisk as wildcard per identifier.
ExpertViewDevString Comma separated list of attributes (for example ``PixelMask``) or commands which should be set to expert view level. Supports one asterisk as wildcard per identifier.
OperatorViewDevString Comma separated list of attributes (for example ``PixelMask``) or commands which should be set to operator view level. Supports one asterisk as wildcard per identifier. If this property is set, all attributes and commands not listed here will be set to expert view level.