This is historical information of device classes implemented in T3AFG40WaveformGenerator device server.

Use this link to find the valid information.

Development status: New development
Information status: New

Contact:



Class Description


T3AFG40 Waveform Generator controll

Families: MeasureInstruments

Key words:

Platform: Unix Like

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: Teledyne Test Tools

Product:

T3AFG

Bus: Ethernet

Class interface


Attributes:

Name Description
C1BurstStateScalar: DevString Burst mode on or off. ON / OFF
C1GateCycleModeScalar: DevString Gating mode or fixed cycle.GATE / NCYC
C1NbCycleMaxScalar: DevLong Maximal number of cycles if NCYC is chosen. -1 -> INF
C1DelayScalar: DevDouble Delay
C1WaveformScalar: DevString Wafeform. SQUARE / PULSE / SINE
C1FrequencyScalar: DevDouble
C1AmplitudeScalar: DevDouble
C1OffsetScalar: DevDouble
C1DutyScalar: DevDouble Duration of the high signal in a cycle in %
C1RiseScalar: DevDouble Rising time for pulse
C1FallScalar: DevDouble Falling time for pulse
C1TriggerScalar: DevString Trigger signal. EXT/INT

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.

Pipes:

Properties:

Name Description
IPAddressDevString IPaddress of the device
PortNbDevLong Port Number

13 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



6 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Feb 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Feb 2021, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



13 Feb 2021, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:20 Feb 2021, 3:46 a.m.