Class Description
Class for controlling the high resolution post-monochromator in p22
Families: BeamlineComponents
Key words:
Platform: Unix Like
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
Name | Description |
---|---|
PositionScalar: DevDouble | Monochromator energy |
UnitLimitMinScalar: DevDouble | — |
UnitLimitMaxScalar: DevDouble | — |
CwLimitScalar: DevLong | — |
CcwLimitScalar: DevLong | — |
SlewRateScalar: DevDouble | — |
PositionSimScalar: DevDouble | Monochromator energy |
CrystalScalar: DevLong | — |
ResultSimSpectrum: DevString | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
StopMoveInput: DevVoid Output: DevVoid |
Stop energy movement |
CalibrateInput: DevDouble New position value Output: DevVoid |
Calibrate the motor: current position is calibrated to be the value given as an argument |
ChangeCrystalAndRecalibrateInput: DevLong Crystal number Output: DevVoid |
Change the crystal and recalibrate the motors with hardcoded constants. |
Pipes:
Properties:
Name | Description |
---|---|
BraggDeviceDevString | Name of the Tango device for the bragg angle |
BraggOffsetC0DevDouble | Bragg Offset for crystals 0, 2 and 4 |
BraggOffsetC1DevDouble | Bragg Offset for crystals 1 and 3 |
Updated:
The device class has been updated.
You can see previous version here .
6 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
30 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
9 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
2 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
25 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
18 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
11 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
4 Sep 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
28 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
21 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
14 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
7 Aug 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
31 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
24 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
17 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
10 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
3 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
26 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
19 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
12 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
5 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
30 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
29 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
15 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
8 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
1 May 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
24 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
17 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
10 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
3 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
27 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
13 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
6 Mar 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
27 Feb 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Feb 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
13 Feb 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
6 Feb 2021, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
30 Jan 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 Jan 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Jan 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
9 Jan 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
2 Jan 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
26 Dec 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
19 Dec 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
12 Dec 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
5 Dec 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
28 Nov 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
21 Nov 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
14 Nov 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
7 Nov 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
31 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
24 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
17 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
10 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
3 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
26 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
19 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
12 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
5 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
29 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
15 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
8 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
1 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
25 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
18 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
11 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
4 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
27 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
13 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
6 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
30 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
30 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
9 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
2 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
25 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
18 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
11 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
4 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
28 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
21 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
14 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
7 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
29 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
15 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
8 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
1 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
25 Jan 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
18 Jan 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
11 Jan 2020, DS Admin
Created:
The device class has been added to catalogue.