This is historical information of device classes implemented in MuxSwitcher device server.
Use this link to find the valid information.
Development status:
New development
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/OtherInstruments/MuxSwitcher
Contact:
Class Description
This device is a Device Multiplexer SWitcher . Switching the Mux is done through a Socket Server TCP/IP embeded in a RasperryPI3 board
Families: OtherInstruments
Key words:
Platform: Unix Like
Language: Cpp
License: GPL
Contact:
Hardware
Manufacturer: SOLEIL
Bus: TCP/UDP
Class interface
Attributes:
Name | Description |
---|---|
muxNumScalar: DevUShort | The Mux number . |
muxNumHistorySpectrum: DevUShort | History of values of the muxNum |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
ConnectInput: DevVoid Output: DevVoid |
Connect to Server TCP/IP |
DisconnectInput: DevVoid Output: DevVoid |
Disconnect from Server TCP/IP |
SendAnyCmdInput: DevString Output: DevVoid |
Send any command (string) to Server TCP/IP |
ClearHistoryInput: DevVoid Output: DevVoid |
Clear MuxNumHistory attribute |
Pipes:
Properties:
Name | Description |
---|---|
ServerIPDevString | The Address of the Server TCP/IP embeded on Rasperry board |
ServerPortDevUShort | The port of the Server TCP/IP embeded on Rasperry board |
RcvEOLDevString | Define the EOL of messages received from Server Tcp/Ip <CR> available values :<CR> CR<CR> LF<CR> FF<CR> HT<CR> VT<CR> SPACE<CR> NUL<CR> |
SendEOLDevString | Define the EOL of messages sent to Server Tcp/Ip <CR> available values :<CR> CR<CR> LF<CR> FF<CR> HT<CR> VT<CR> SPACE<CR> NUL<CR> |
MuxNumMinDevUShort | Define the minimum muxNum value |
MuxNumMaxDevUShort | Define the maximum muxNum value |
AutoConnectDevBoolean | Auto Connect at Init |
RefreshAlwaysMuxNumDevBoolean | Define if muxNum must be always refreshed from the Server IP.<CR> Otherwise, refresh is done only when user write at muxNum attribute. |
Updated:
The device class has been updated.
You can see previous version here .
26 Sep 2020, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
19 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
12 Sep 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
5 Sep 2020, DS Admin
Created:
The device class has been added to catalogue.