Class Description


Class for controlling the in-vacuum CCD camera model GE-VAC 2048 2048 BI from GreatEyes

Families: Acquisition

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: GreatEyes

Product:

GE-VAC 2048 2048 BI

Bus: USB

Class interface


Attributes:

Name Description
ReadoutSpeedScalar: DevLong Set readout speed. Read last set value. Sets pixel clock to [0..6] 0 -> 1 MHz 3 -> 3 MHz 5 -> 500 kHz 6 -> 50 kHz
ExposureTimeScalar: DevDouble Set exposure time, read last set value.
BinningXScalar: DevLong Number of pixels [1...numPixelInX] to be binned in x-direction (if supported by CCD). 0 -> no binning
BinningYScalar: DevLong Number of pixels [1...numPixelInY] to be binned in y-direction. 0 -> no binning
GainScalar: DevLong 0 -> Low ( Max. Dyn. Range ) 1 -> Std ( High Sensitivity )
CapacityModeScalar: DevLong 0 -> Standard ( Low Noise ) 1 -> Extended ( High Signal )
CropModeXScalar: DevLong Number of columns to readout
CropModeYScalar: DevLong Number of lines to readout
CropModeScalar: DevLong 1 -> active
CoolingTemperatureLevelScalar: DevLong Adjust temperature of CCD sensoR
CoolingOffOnScalar: DevLong Switch temperature control off/on (0/1)
SensorTemperatureScalar: DevLong
BacksideTemperatureScalar: DevLong
FileDirScalar: DevString Path to the dector image files.
FilePrefixScalar: DevString The prefix of the image files to be created. The full image file name will be composed as <br /> <b>prefix_number.postfix </b> <br /> when acquiring images.
FileStartNumScalar: DevLong The file number used when saviing an image.
BiasCorrectionScalar: DevLong 0 -> disable, 1->enable
SyncOutputScalar: DevLong 1 -> Sets the “SYNC” TTL trigger output to TTL high level. 0 -> Sets the “SYNC” TTL trigger output to TTL low level.
OpenShutterScalar: DevLong 0 -> close 1 -> open 2 -> auto shutter
ShutterOpenTimeScalar: DevDouble Time to wait before the start of the exposure to ensure that the shutter is fully opened.
ShutterCloseTimeScalar: DevDouble Time to wait after exposure and before starting the readout to ensure that the shutter is fully closed.
SyncOutputEnabledScalar: DevLong 0 -> sync-output disabled 1 -> sync-output enabled
ShutterControlEnabledScalar: DevLong 0 -> shutter control disabled 1 -> shutter control enabled
TriggerModeScalar: DevLong 0 -> internally triggered
TriggerTimeoutScalar: DevFloat Trigger timeout in seconds. Only used if trigger mode is 1
LastSavedImageScalar: DevString Complete path of the last saved image
SaveImageFilesScalar: DevLong If 0 image files are not saved
ImageImage: DevUShort

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartAcqInput: DevVoid
Output: DevVoid
Start acquisition
StopAcqInput: DevVoid
Output: DevVoid
Stop acquisition
PrepareAcqInput: DevVoid
Output: DevVoid
Update settings. Automatically called if settings have been changed and StartAcq is called before preparing the acquisition.

Pipes:

Properties:

15 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



8 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



1 Aug 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



11 Jul 2020, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



4 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



6 Jun 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



9 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



2 May 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



18 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



11 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Apr 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



28 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



21 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



14 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



7 Mar 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



29 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



15 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



8 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



1 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 May 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



9 Feb 2019, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:11 Jul 2020, 3:02 a.m.