Class Description


Device to read back the integarted voltage value, converted in current with the formula : <Br> current = volatge * ( (dcctRange / nbTurns) / fullScale )

Families: MeasureInstruments

Key words:

Platform: All Platforms

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: Fluke

Product:

8508A

Bus: GPIB

Class interface


Attributes:

Name Description
voltageScalar: DevDouble Displays the read back voltage value
currentScalar: DevDouble The computed current value. <Br> Formula used : (DCCTRange / NbTurns) / IMax <Br>
factorScalar: DevDouble Factor value to convert the voltage value in current.
dcctRangeScalar: DevDouble DCCT Range value used in the formula to convert voltage in current.
nbTurnsScalar: DevDouble The number of turns value. (used in the formula to convert voltage in current)
fullScaleScalar: DevDouble The full scale value in ampere (used in the formula to convert voltage in current).

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
FilterONInput: DevVoid
no argin
Output: DevVoid
no argout
Inserts a hardware analog filter into the signal path.
FilterOFFInput: DevVoid
no argin
Output: DevVoid
no argout
Removes the insterted hardware analog filter into the signal path.
FastONInput: DevVoid
no argin
Output: DevVoid
no argout
Reduces the A-D integration time, for faster conversions.
FastOFFInput: DevVoid
no argin
Output: DevVoid
no argout
Disables the A-D integration time.
ResetInput: DevVoid
no argin
Output: DevVoid
no argout
Resets the Fluke device
ClearErrorInput: DevVoid
no argin
Output: DevVoid
no argout
Command to clear last error message

Pipes:

Properties:

Name Description
CommunicationLinkDevString Mandatory <Br> Device which handles the communication protocol
ConfigurationArray of DevString List of commands to configure the Fluke

19 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Feb 2020, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



30 Nov 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



19 Oct 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



12 Oct 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



5 Oct 2019, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:22 Feb 2020, 3:34 a.m.