This is historical information of device classes implemented in EA520002APowerSupply device server.

Use this link to find the valid information.

Development status: New development
Information status: Updated

Contact: tnunez@mail.desy.de



Class Description


EA-PS 5000er serie - Power Supply control via modbus

Families: PowerSupply

Key words:

Platform: Unix Like

Language: Python

License: GPL

Contact: tnunez@mail.desy.de

Hardware


Manufacturer: Elektro Automatik

Product:

PS 5200-02 A

Bus: Modbus

Class interface


Attributes:

Name Description
DCOutputScalar: DevLong 0->off, 1->on
SetVoltageScalar: DevDouble
SetCurrentScalar: DevDouble
VoltageScalar: DevDouble Current Voltage
CurrentScalar: DevDouble Current current
RemoteModeScalar: DevLong 0 -> off, 1 ->on
SetPowerScalar: DevDouble
PowerScalar: DevDouble Current power
AlarmScalar: DevLong 1 if any alarm is active
AlarmInfoScalar: DevString
WarningSenseScalar: DevLong 1 if active
RegulationModeScalar: DevLong 0 -> cv 1 -> cc 2 -> cp

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.

Pipes:

Properties:

Name Description
SerialPortDevString Serial Port of the device. Ex. /dev/ttyACM0

Added by:dadmin on:16 Nov 2019, 4:13 a.m.