This is historical information of device classes implemented in KromoTX1easyXAFS device server.
Use this link to find the valid information.
Development status:
Released,
Release: Release_1_1
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Acquisition/2D/KromoTX1easyXAFS
Contact:
Class Description
Class for controlling the Kromo-TX1 color tender X-ray camera from easyXAFS
Families: Acquisition
Key words:
Platform: Unix Like
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: easyXAFS
Product:
Kromo-TX1 Color Tender X-ray camera
Bus: USB
Class interface
Attributes:
Name | Description |
---|---|
ExpositionTimeScalar: DevDouble | — |
GainScalar: DevLong | Read gain from the camera. The set value is given in the property Gain of the tango device. |
FramesPerSecondScalar: DevDouble | Read the fps from the camera. The value is set from the property of the tango device. If HighSpeedMode == 0 -> max value is 80 If HighSpeedMode == 1 -> max values is 170 |
HighSpeedModeScalar: DevLong | 0-> off, 1-> on |
FileDirScalar: DevString | Save directory |
FilePrefixScalar: DevString | Prefix of the file were the data and parameters are save. Data is saved in [FilePrefix][FileIndex]_array.npy. Parameters in [FilePrefix]_parameters. If the file [FilePrefix][FileIndex]_parameters exists, the data are loaded and not new data are taken. |
TemperatureScalar: DevDouble | — |
WindowMinScalar: DevLong | Show current window (set in the property). |
WindowMaxScalar: DevLong | Show current window (set in the property). |
FileIndexScalar: DevLong | Index to append to the file name. It will be increased by one after use. Avoid loading of files if not explicitly wanted. |
TotalAverageCountsScalar: DevDouble | Total counts in RoI (depends on PhotonValue) |
PhotonValueScalar: DevDouble | Average pixel value counted in the detector |
RoI1MinScalar: DevLong | RoI for computing counts |
RoI1MaxScalar: DevLong | RoI for computing counts |
RoI2MinScalar: DevLong | RoI for computing counts |
RoI2MaxScalar: DevLong | RoI for computing counts |
RoI1CountsScalar: DevDouble | Counts in RoI1 |
RoI2CountsScalar: DevDouble | Counts in RoI2 |
PixelSizeScalar: DevDouble | Resize the pixel. If -1 is not used. |
DataSpectrum: DevDouble | — |
FrameImage: DevDouble | Depends on PhotonValue |
ResizedFrameImage: DevDouble | Resized frame using PixelSize attribute. |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
StartAcquisitionInput: DevVoid Output: DevVoid |
Start acquisition |
StopAcquisitionInput: DevVoid Output: DevVoid |
— |
Pipes:
Properties:
Name | Description |
---|---|
kromo_pidsArray of DevLong | Process ids from last server running. Filled by the tango device. |
WindowMinDevLong | Window min (for photon processing) |
WindowMaxDevLong | Window max (for photon processing) |
ThresholdDevLong | Threshold |
DeclusterDevLong | 0-> false, 1->true |
GainDevLong | Gain of the camera |
FramesPerSecondDevDouble | Frames per second If HighSpeedMode == 0 -> max value is 80 If HighSpeedMode == 1 -> max values is 170 |
AnalysisModeDevLong | If 1, it works without detector, only loading files. |
README
b'It can not be started with Astor if the remaining threads are not killed\nper hand. The starting script and the Tango Server kill them at init.'
Updated:
The device class has been updated.
You are looking at this version now.
28 Apr 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
21 Oct 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
16 Sep 2017, Piotr Goryl
Created:
The device class has been added to catalogue.