This is historical information of device classes implemented in LambdaOnlineAnalysis device server.

Use this link to find the valid information.

Development status: New development
Information status: Updated

Contact:



Class Description


Perfoming online analysis with Lambda images

Families: Acquisition

Key words:

Platform: Unix Like

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
MaskFileScalar: DevString Name of the nxs file containing the pixel mask.
ApplyMaskScalar: DevLong 1 if mask file has to be applied.
MaximumValueScalar: DevDouble Maximum value in detector
CountsRoI1Scalar: DevDouble
NbRoIsScalar: DevLong Number of defined RoIs
ProjectionXRoI1Spectrum: DevDouble
ProjectionYRoI1Spectrum: DevDouble
RoIsSpectrum: DevLong Limits RoIs 1: x1, y1, x2, y2, x3, y3, x4, y4 Each 4 values are a RoI
MaximumValuesSpectrum: DevDouble Maximum values RoIs
MeanValuesSpectrum: DevDouble Mean values RoIs
ImageRoI1Image: DevDouble
MaskImage: DevLong

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartAnalysisInput: DevVoid
Output: DevVoid
StopAnalysisInput: DevVoid
Output: DevVoid

Pipes:

Properties:

Name Description
LambdaDeviceDevString Lambda tango device to connect to.
DefaultRoIDevString Default value for the RoI. String x1, x2, y1, y2

5 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



24 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



30 Mar 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Oct 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



29 Sep 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:13 Oct 2018, 3:06 a.m.