This is historical information of device classes implemented in LambdaOnlineAnalysis device server.
Use this link to find the valid information.
Development status:
New development
Information status: Updated
Contact:
Class Description
Perfoming online analysis with Lambda images
Families: Acquisition
Key words:
Platform: Unix Like
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
Name | Description |
---|---|
CountsRoI1Scalar: DevDouble | — |
MaskFileScalar: DevString | Name of the nxs file containing the pixel mask. |
ApplyMaskScalar: DevLong | 1 if mask file has to be applied. |
MaximumValueScalar: DevDouble | Maximum value in detector |
NbRoIsScalar: DevLong | Number of defined RoIs |
ProjectionXRoI1Spectrum: DevDouble | — |
ProjectionYRoI1Spectrum: DevDouble | — |
RoIsSpectrum: DevDouble | Limits RoIs 1: x1, y1, x2, y2, x3, y3, x4, y4 Each 4 values are a RoI |
MaximumValuesSpectrum: DevDouble | Maximum values RoIs |
MeanValuesSpectrum: DevDouble | Mean values RoIs |
ImageRoI1Image: DevDouble | — |
MaskImage: DevLong | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
StartAnalysisInput: DevVoid Output: DevVoid |
— |
StopAnalysisInput: DevVoid Output: DevVoid |
— |
Pipes:
Properties:
Name | Description |
---|---|
LambdaDeviceDevString | Lambda tango device to connect to. |
DefaultRoIDevString | Default value for the RoI. String x1, x2, y1, y2 |
5 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
24 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
30 Mar 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
13 Oct 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
29 Sep 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
24 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
30 Mar 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
13 Oct 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
29 Sep 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2
on:29 Sep 2018, 3:06 a.m.