This is historical information of device classes implemented in XMCD device server.

Use this link to find the valid information.

Development status: Released, Release: Release_2_1
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/OtherInstruments/XMCD
Contact:



Class Description


Computes a current for normalization using the PiLC.

Families: Miscellaneous

Key words:

Platform: Unix Like

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: DESY

Product:

PiLC

Bus: Not Applicable

Class interface


Attributes:

Name Description
IntensityScalar: DevDouble
IPlusScalar: DevDouble ItPlus/I0Plus
IMinusScalar: DevDouble ItMinus/I0Minus
ItPlusScalar: DevLong
I0PlusScalar: DevLong
ItMinusScalar: DevLong
I0MinusScalar: DevLong
GateStatusScalar: DevLong
MirrorDelay1Scalar: DevFloat Reads last written value. The write value is rounded to multiples of 5 ns.
MirrorDelay2Scalar: DevFloat Reads last written value. The write value is rounded to multiples of 5 ns.
ClockCounterScalar: DevDouble
I0Plus1Scalar: DevLong
I0Plus2Scalar: DevLong
I0Minus1Scalar: DevLong
I0Minus2Scalar: DevLong
TGAFrequencyScalar: DevDouble Frequency of the PGA. Used to convert PiLC counts to time.
ClockTimeScalar: DevDouble
IpImDiffScalar: DevDouble Iplus - Iminus
IpImXasScalar: DevDouble - Iplus - Iminus
ItPlus2Scalar: DevLong
ItMinus2Scalar: DevLong
ModeScalar: DevLong Mode for Iplus and Iminus calculation: 0 -> absortion, 1 -> fluorescence/diffraction
ModeInfoScalar: DevString Shows selected mode in Mode attribute.
IDirectionScalar: DevLong 0 -> I-, 1 -> I+

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.

Pipes:

Properties:

Name Description
PiLCDeviceDevString Name of the PiLCDevice connecting to the hw.
InitPiLCAtStartDevLong If set to 1, the PiLC is initilized when the server is started.

14 May 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



26 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Aug 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:25 Aug 2018, 4:08 a.m.