This is historical information of device classes implemented in FMBOxfDCMEnergy device server.
Use this link to find the valid information.
Development status:
Released,
Release: Release_3_2
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/BeamlineComponents/Monochromators/FMBOxfDCMEnergy
Contact:
Class Description
Class for controlling the FMB Oxford Double Crystal Monochromator
Families: Motion
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: Serial Line
Class interface
Attributes:
Name | Description |
---|---|
BraggAngleScalar: DevDouble | — |
ExitOffsetScalar: DevDouble | — |
PhasingModeScalar: DevLong | 0 -> Soft Phasing Mode\n1-> Forced Phasing Mode |
CrystalScalar: DevLong | Select the crystal type for the energy move. 0 -> CrystalSi111 1 -> CrystalSi311 2->Si111 ChannelCut 3-> Si311 as Si111 |
PositionScalar: DevDouble | Monochromator Energy |
UnitLimitMaxScalar: DevDouble | Software limit for maximum Position |
UnitLimitMinScalar: DevDouble | Software limit for minimum Position |
PositionSimScalar: DevDouble | — |
UpdateStatusRateScalar: DevDouble | Rate for checking status of the motors during a movement. |
PositionAccuracyScalar: DevDouble | Reads PositionAccuray from Bragg motor device and transforme it to eV. |
ExitOffsetC1Scalar: DevDouble | ExitOffset to be restored when crystal is changed to 1 with the ChangeCrystalAndRecalibrate command. |
ExitOffsetC0Scalar: DevDouble | ExitOffset to be restored when crystal is changed to 0 with the ChangeCrystalAndRecalibrate command. |
MaskMoveMotorsScalar: DevLong | Masked motors will not be set the state to FAULT if they can not be moved. 1 (Perp) & 2 (Par) |
PseudoChannelCutModeScalar: DevLong | If 1 the PseudoChannelCutMode is activated: \nparallel axis not moved for small angles. |
BraggOffsetScalar: DevDouble | Offset used only in p01 when the crystal Si311 is used as Si111 |
BraggOffset0Scalar: DevDouble | Value to be restored in BraggOffset if crystal is changed to Si111 - crystal 0 (only for p01). |
BraggOffset1Scalar: DevDouble | Value to be restored in BraggOffset if crystal is changed to Si311 - crystal 1 (only for p01). |
BraggOffset3Scalar: DevDouble | Value to be restored in BraggOffset if crystal is changed to Si311 as Si111 - crystal 3 (only for p01). |
ResultSimSpectrum: DevString | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
StartUpInput: DevVoid Output: DevVoid |
Automated system startup |
ShutdownInput: DevVoid Output: DevVoid |
Automatic system shutdown |
CheckErrorInput: DevVoid Output: DevLong Error code |
Read the error flags and return an error: bit 1 BraggAxisInErr bit 2 PerpAxisInErr bit 3 ParAxisInErr bit 4 TmOutErrFlag bit 5 Skipped |
StopMoveInput: DevVoid Output: DevVoid |
Stop a movement |
HomeAllInput: DevVoid Output: DevVoid |
Home motors for version 10. |
CalibrateInput: DevDouble Value to be calibrated Output: DevLong Completion status |
Calibrate the energy: current energy is calibrated to be the value given as an argument |
HomeJacksInput: DevVoid Output: DevVoid |
Home jack motors for DCM GKSS |
HomeLateralsInput: DevVoid Output: DevVoid |
Home lateral motors for DCM GKSS |
ChangeCrystalAndRecalibrateInput: DevLong Crystal number Output: DevVoid |
Change the crystal and recalibrate the motors with hardcoded constants. |
ClearStateInput: DevVoid Output: DevVoid |
Set state to ON. |
BrakeWithCorrectionInput: DevVoid Output: DevVoid |
Prepare the system for movements with a fixed energy and less vibrations. |
BrakeInput: DevVoid Output: DevVoid |
Activate the Bragg brake in the current position |
Pipes:
Properties:
Name | Description |
---|---|
FMBOxfDCMCtrlDeviceDevString | FMBOxfDCMCtrl server for RS232 interface |
SimulationModeDevULong | 0 -> real mode, 1 -> simulation mode |
VersionDevLong | 0 -> old , 1 -> new |
BraggDeviceDevString | Name of the Tango device for the Bragg motor |
FMBOxfDCMCtrlDevice2DevString | Second controller in case of motors not controlled via global movements (version 10) |
ParDeviceDevString | Name of the Tango device for the parallel motor |
PerpDeviceDevString | Name of the Tango device for the perpendicular motor |
Bragg2DeviceDevString | Tango Device Name for the second bragg motor (version 10, DCM gkss) |
LongitudinalDeviceDevString | Tango Device Name for the longitudinal motor (version 10, DCM gkss) |
ChannelCutGapDevFloat | Gap for the channel cut. |
BraggOffsetC0DevDouble | Bragg Offset for crystal 0 |
BraggOffsetC1DevDouble | Bragg Offset for crystal 1 |
BraggOffsetC2DevDouble | Bragg Offset for crystal 2 |
ParOffsetC0DevDouble | Parallel Offset crystal 0 |
ParOffsetC1DevDouble | Parallel Offset crystal 1 |
ParOffsetC2DevDouble | Parallel offset crystal 2 |
PerpOffsetC0DevDouble | Perpendicular offset crystal 0 |
PerpOffsetC1DevDouble | Perpendicular Offset crystal 1 |
PerpOffsetC2DevDouble | Perpendicular Offset crystal 2 |
Bragg2OffsetC0DevDouble | Bragg2 offset crystal 0 |
Bragg2OffsetC1DevDouble | Bragg2 offset crystal 1 |
Bragg2OffsetC2DevDouble | Bragg2 offset crystal 2 |
LongitudinalOffsetC0DevDouble | Longitudinal offset crystal 0 |
LongitudinalOffsetC1DevDouble | Longitudinal Offset crystal 1 |
LongitudinalOffsetC2DevDouble | Longitudinal Offset crystal 2 |
BeamlineDevLong | Beamline number. Needed for shutter, |
DCrystalSI111DevDouble | Lattice spacing for SI111 crystal. If value is not set or set to 0 or negative a default value is taken. |
DCrystalSI311DevDouble | Lattice spacing for SI311 crystal. If value is not set or set to 0 or negative a default value is taken. |
BraggOffsetC3DevDouble | Bragg Offset for crystal 3 |
ParOffsetC3DevDouble | Parallel Offset crystal 3 |
PerpOffsetC3DevDouble | Perpendicular offset crystal 3 |
README
b'\nThe FMBOxfDCMEnergy class uses FMBOxfDCMCtrl and FMBOxfDCMMotor\n\n # ./Do.pl [nodeName]\n\ncreates a server and copies it to /usr/local/bin/server or the\nsame directory on nodeName. \n\n # make using_trunk=1\n\nmakes the server by using the trunk dirs as input\n\n # make\n\ncreates the server by using the current version dir'
Updated:
The device class has been updated.
You can see previous version here .
22 May 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
25 Aug 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
26 May 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
31 Mar 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
5 Jan 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.