This is historical information of device classes implemented in AcqPrincetonSwing device server.
Use this link to find the valid information.
Development status:
New development
Information status: Updated
Contact:
Class Description
Princeton CCD acquisition device
Families: Acquisition
Key words: 2D
Language: Cpp
Contact:
Class interface
Attributes:
Name | Description |
---|---|
acqModeScalar: DevLong | — |
binningSpectrum: DevLong | — |
checkTemperatureScalar: DevBoolean | — |
depthScalar: DevLong | — |
exposureScalar: DevDouble | — |
fileFormatScalar: DevString | — |
fileNameScalar: DevString | — |
fileParmsSpectrum: DevString | — |
framesScalar: DevLong | — |
heightScalar: DevLong | — |
imageImage: DevUShort | — |
nbROIScalar: DevLong | — |
numFrameScalar: DevLong | — |
roiSpectrum: DevLong | — |
roi2Spectrum: DevLong | — |
rotateImageScalar: DevLong | — |
saturationScalar: DevDouble | — |
saturationAlarmScalar: DevDouble | — |
saturationMaxScalar: DevDouble | — |
shutterModeScalar: DevLong | — |
temperatureScalar: DevDouble | — |
timingScalar: DevDouble | — |
triggerScalar: DevLong | — |
useROIScalar: DevBoolean | — |
widthScalar: DevLong | — |
shutterCloseDelayScalar: DevDouble | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
CloseInput: DevVoid Output: DevVoid |
Frees the current camera, prepares it for power-down |
GetParamInput: DevString Output: DevString |
None. |
OpenInput: DevVoid Output: DevVoid |
Reserves and initializes the camera hardware - Detects the characteristics of the CCD : width, height, depth wich can be read using the device`s attributes - Sets the desired temperature |
SetParamInput: DevVarStringArray Output: DevVoid |
None. |
StartInput: DevVoid Output: DevVoid |
Starts exposing - the desired exposing mode (continuous or sequence) must be previously defined with SetMode() command |
StopInput: DevVoid Output: DevVoid |
Stops the current sequence of exposing |
Pipes:
Properties:
Name | Description |
---|---|
CamIdDevString | Camera identifier |
CamTypeDevLong | Camera type 0 = Princeton |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You are looking at this version now.
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:22 Feb 2018, 2:43 p.m.