This is historical information of device classes implemented in PulseGeneration device server.

Use this link to find the valid information.

Development status: Released, Release: release_1_1_12
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/CounterTimer/NI/PulseGeneration
Contact:



Class Description


2 modes (depending on properties):
-Mode Retrig: Generate a single pulse on 8 counters each time a trigger is received. -Mode Continuous: Generate pulses continuously on 8 counters. The delay and the width of each pulse is configurable.

Families: CounterTimer

Key words: NI

Language: Cpp

License:

Contact:

Class interface


Attributes:

Name Description
generationTypeScalar: DevString
pulseNumberScalar: DevLong
counter0EnableScalar: DevBoolean
initialDelay0Scalar: DevDouble
delayCounter0Scalar: DevDouble
pulseWidthCounter0Scalar: DevDouble
counter1EnableScalar: DevBoolean
initialDelay1Scalar: DevDouble
delayCounter1Scalar: DevDouble
pulseWidthCounter1Scalar: DevDouble
counter2EnableScalar: DevBoolean
initialDelay2Scalar: DevDouble
delayCounter2Scalar: DevDouble
pulseWidthCounter2Scalar: DevDouble
counter3EnableScalar: DevBoolean
initialDelay3Scalar: DevDouble
delayCounter3Scalar: DevDouble
pulseWidthCounter3Scalar: DevDouble
counter4EnableScalar: DevBoolean
initialDelay4Scalar: DevDouble
delayCounter4Scalar: DevDouble
pulseWidthCounter4Scalar: DevDouble
counter5EnableScalar: DevBoolean
initialDelay5Scalar: DevDouble
delayCounter5Scalar: DevDouble
pulseWidthCounter5Scalar: DevDouble
counter6EnableScalar: DevBoolean
initialDelay6Scalar: DevDouble
delayCounter6Scalar: DevDouble
pulseWidthCounter6Scalar: DevDouble
counter7EnableScalar: DevBoolean
initialDelay7Scalar: DevDouble
delayCounter7Scalar: DevDouble
pulseWidthCounter7Scalar: DevDouble

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartInput: DevVoid
Output: DevVoid
Start generations of pulses.
StopInput: DevVoid
Output: DevVoid
Stop generations of pulses.
AbortInput: DevVoid
Output: DevVoid
Abort generations.
ResetBoardInput: DevVoid
Output: DevVoid
Reset the physical board. After this command, the board is in an unknown state (no more configured). The device must be initialized.
GetDriverVersionInput: DevVoid
Output: DevString
Get the current version of the driver installed for NI counter boards.
GetBoardsInChassisInput: DevVoid
Output: DevString
Get a string containing all the boards names (from NI) present in the chassis where this device is running. This names are defined in MAX.
GetBoardTypeInput: DevString
Output: DevString
Returns the type (ex: PXI-6602) of a specified board.

Pipes:

Properties:

Name Description
TriggerSourceDevString The name of the terminal for the input trigger as specified by NI (PFIxx). The trigger can be configured as following: - for finite and continuous modes, this trigger can be used as a start trigger (cf UseExtStartTrigger). If no start trigger is used, a counter of the board will be used to start all the other counters. - for retrig mode, each trigger will launch the generation of a pulses train. So the possible values are PFIxx
BoardNameDevString The name of the board.
AutoStartDevBoolean If true, the generation will start at device startup and when command ``Init`` is executed.
ClockDevString The clock used. Possible values are ``INTERNAL`` or ``PFIxx``, with xx the pin number.
ExternalFrequencyDevDouble In case of using an external clock, the frequency of this clock in Hz.
IdleStateCounter0DevString cCan be LOW or HIGH.
IdleStateCounter1DevString
IdleStateCounter2DevString
IdleStateCounter3DevString
IdleStateCounter4DevString
IdleStateCounter5DevString
IdleStateCounter6DevString
IdleStateCounter7DevString
UseExtStartTriggerDevBoolean If true, use the TriggerSource to start the generation in Finite or Continuous Mode.
TriggerEdgeDevString values : POSITIVE or NEGATIVE. Set if the external trigger is posivite edge or negative edge.

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:22 Feb 2018, 2:33 p.m.