Class Description
- The device analyzes images accessible on another remote device,
- and proposes the following (selectable) features : - in preprocessing : rotation, mirroring, gamma correction - ROI (Region Of Interest), either user-defined or automatic by blob analysis - image moments (mean intensity, centroid, variance, skew) - maximal intensity (to monitor saturation for example) - ellipse fitting when automatic ROI is desired - profiles with corresponding gaussian fit - 2D gaussian fit of the image
Families: Calculation
Key words:
Platform: All Platforms
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
Name | Description |
---|---|
MeanIntensityScalar: DevDouble | — |
EnableImageStatsScalar: DevBoolean | — |
EnableProfilesScalar: DevBoolean | — |
EnableHistogramScalar: DevBoolean | — |
EnableUserROIScalar: DevBoolean | — |
EnableAutoROIScalar: DevBoolean | — |
Enable2DGaussianFitScalar: DevBoolean | — |
ComputationPeriodScalar: DevLong | — |
EstimComputTimeScalar: DevLong | — |
RotationScalar: DevLong | — |
HorizontalFlipScalar: DevBoolean | — |
BitsPerPixelScalar: DevLong | — |
HistogramNbBinsScalar: DevLong | — |
HistogramRangeMinScalar: DevLong | — |
HistogramRangeMaxScalar: DevLong | — |
GammaCorrectionScalar: DevDouble | — |
AutoROIMagFactorXScalar: DevDouble | — |
AutoROIMagFactorYScalar: DevDouble | — |
AutoROIThresholdScalar: DevLong | — |
BgSubstractionScalar: DevDouble | — |
AlarmZoneScalar: DevLong | — |
PixelSizeXScalar: DevDouble | — |
PixelSizeYScalar: DevDouble | — |
OpticalMagnificationScalar: DevDouble | — |
ProfileFitFixedBgScalar: DevBoolean | — |
LineProfileOriginXScalar: DevLong | — |
LineProfileOriginYScalar: DevLong | — |
LineProfileEndXScalar: DevLong | — |
LineProfileEndYScalar: DevLong | — |
LineProfileThicknessScalar: DevLong | — |
ChamberOffsetXScalar: DevDouble | — |
ChamberOffsetYScalar: DevDouble | — |
ChamberCentroidXScalar: DevDouble | — |
ChamberCentroidYScalar: DevDouble | — |
ChamberXProjFitCenterScalar: DevDouble | — |
ChamberYProjFitCenterScalar: DevDouble | — |
UserROIOriginXScalar: DevLong | — |
UserROIOriginYScalar: DevLong | — |
UserROIWidthScalar: DevLong | — |
UserROIHeightScalar: DevLong | — |
AutoROIFoundScalar: DevBoolean | — |
AutoROIOriginXScalar: DevLong | — |
AutoROIOriginYScalar: DevLong | — |
AutoROIWidthScalar: DevLong | — |
AutoROIHeightScalar: DevLong | — |
MaxIntensityScalar: DevDouble | — |
CentroidXScalar: DevDouble | — |
CentroidYScalar: DevDouble | — |
CentroidSaturatedScalar: DevBoolean | — |
CentroidSaturationRegionSideScalar: DevLong | — |
CentroidSaturationRegionThresholdScalar: DevLong | — |
VarianceXScalar: DevDouble | — |
VarianceYScalar: DevDouble | — |
CovarianceXYScalar: DevDouble | — |
CorrelationXYScalar: DevDouble | — |
SkewXScalar: DevDouble | — |
SkewYScalar: DevDouble | — |
SkewX2YScalar: DevDouble | — |
SkewXY2Scalar: DevDouble | — |
XProjFitConvergedScalar: DevBoolean | — |
XProjFitCenterScalar: DevDouble | — |
XProjFitMagScalar: DevDouble | — |
XProjFitSigmaScalar: DevDouble | — |
XProjFitFWHMScalar: DevDouble | — |
XProjFitBGScalar: DevDouble | — |
XProjFitChi2Scalar: DevDouble | — |
YProjFitConvergedScalar: DevBoolean | — |
YProjFitCenterScalar: DevDouble | — |
YProjFitMagScalar: DevDouble | — |
YProjFitSigmaScalar: DevDouble | — |
YProjFitFWHMScalar: DevDouble | — |
YProjFitBGScalar: DevDouble | — |
YProjFitChi2Scalar: DevDouble | — |
LineProfileFitConvergedScalar: DevBoolean | — |
LineProfileFitCenterScalar: DevDouble | — |
LineProfileFitMagScalar: DevDouble | — |
LineProfileFitSigmaScalar: DevDouble | — |
LineProfileFitFWHMScalar: DevDouble | — |
LineProfileFitBGScalar: DevDouble | — |
LineProfileFitChi2Scalar: DevDouble | — |
GaussianFitConvergedScalar: DevBoolean | — |
GaussianFitMagnitudeScalar: DevDouble | — |
GaussianFitCenterXScalar: DevDouble | — |
GaussianFitCenterYScalar: DevDouble | — |
GaussianFitVarianceXScalar: DevDouble | — |
GaussianFitVarianceYScalar: DevDouble | — |
GaussianFitCovarianceXYScalar: DevDouble | — |
GaussianFitMajorAxisFWHMScalar: DevDouble | — |
GaussianFitMinorAxisFWHMScalar: DevDouble | — |
GaussianFitTiltScalar: DevDouble | — |
GaussianFitBGScalar: DevDouble | — |
GaussianFitChi2Scalar: DevDouble | — |
Fit1DNbIterMaxScalar: DevLong | — |
Fit1DMaxRelChangeScalar: DevDouble | — |
Fit2DNbIterMaxScalar: DevLong | — |
Fit2DMaxRelChangeScalar: DevDouble | — |
XProjFitNbIterScalar: DevLong | — |
XProjFitRelChangeScalar: DevDouble | — |
YProjFitNbIterScalar: DevLong | — |
YProjFitRelChangeScalar: DevDouble | — |
LineProfileFitNbIterScalar: DevLong | — |
LineProfileFitRelChangeScalar: DevDouble | — |
GaussianFitNbIterScalar: DevLong | — |
GaussianFitRelChangeScalar: DevDouble | — |
RmsXScalar: DevDouble | — |
RmsYScalar: DevDouble | — |
XProjSpectrum: DevDouble | — |
XProjFittedSpectrum: DevDouble | — |
XProjErrorSpectrum: DevDouble | — |
YProjSpectrum: DevDouble | — |
YProjFittedSpectrum: DevDouble | — |
YProjErrorSpectrum: DevDouble | — |
LineProfileSpectrum: DevDouble | — |
LineProfileFittedSpectrum: DevDouble | — |
LineProfileErrorSpectrum: DevDouble | — |
HistogramSpectrum: DevFloat | — |
InputImageImage: DevULong | — |
ROIImageImage: DevULong | — |
LineProfileHelperImgImage: DevFloat | — |
GaussianFitParameterCovarianceImage: DevDouble | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
StartInput: DevVoid Output: DevVoid |
None. |
StopInput: DevVoid Output: DevVoid |
None. |
ProcessInput: DevVoid Output: DevVoid |
None. |
SaveCurrentSettingsInput: DevVoid Output: DevVoid |
None. |
GetVersionNumberInput: DevVoid Output: DevString |
None. |
Pipes:
Properties:
Name | Description |
---|---|
AutoROIMagFactorXDevDouble | initial value of AutoROIMagFactorX attribute. if not defined, it is set to 1 |
AutoROIMagFactorYDevDouble | initial value of AutoROIMagFactorY attribute. if not defined, it is set to 1 |
AutoROIMethodDevString | the method used for computing the AutoROI. can be `PROFILES` or `THRESHOLD`. PROFILES method means the AutoROI is computed from the profiles fitted to gaussian functions. THRESHOLD means that the image is first thresholded using the `AutoROIThreshold` attribute then the largest blob is selected. |
AutoStartDevBoolean | if set to `true` and mode is `CONTINUOUS`, the computation starts automatically when the device is launched |
BitsPerPixelDevLong | the initial value of the BitsPerPixel attribute |
ComputationPeriodDevLong | the initial value of the ComputationPeriod attribute |
Enable2DGaussianFitDevBoolean | the initial value of the Enable2DGaussianFit attribute |
EnableAutoROIDevBoolean | the initial value of the EnableAutoROI attribute |
EnableHistogramDevBoolean | the initial value of the EnableHistogram attribute |
EnableImageStatsDevBoolean | the initial value of the EnableImageStats attribute |
EnableProfilesDevBoolean | the initial value of the EnableProfiles attribute |
EnableUserROIDevBoolean | the initial value of the EnableUserROI attribute |
GammaCorrectionDevDouble | the initial value of the GammaCorrection attribute |
HistogramNbBinsDevLong | the initial value of the HistogramNbBins attribute |
HistogramRangeMaxDevLong | the upper bound of the histogram bins. must be |
HistogramRangeMinDevLong | the lower bound of the histogram bins. must be> = 0 |
HorizontalFlipDevBoolean | the initial value of the HorizontalFlip attribute |
ImageAttributeNameDevString | the name of the image attribute to take in ImageDevice |
ImageCounterAttrNameDevString | the name of the imageCounter attribute to take in ImageDevice |
ImageDeviceDevString | the device from which the image is taken |
ModeDevString | ONESHOT or CONTINUOUS |
OpticalMagnificationDevDouble | the initial value of the OpticalMagnification attribute |
PixelSizeXDevDouble | the initial value of the PixelSizeX attribute |
PixelSizeYDevDouble | the initial value of the PixelSizeY attribute |
ProfileFitFixedBgDevBoolean | the initial value of the ProfileFitFixedBg attribute |
RotationDevLong | the initial value of the Rotation attribute |
UserROIOriginXDevLong | The memorized value of userROIOriginX attribute when SaveCurrentSettings command is called. |
UserROIOriginYDevLong | The memorized value of userROIOriginY attribute when SaveCurrentSettings command is called. |
UserROIWidthDevLong | The memorized value of userROIWidth attribute when SaveCurrentSettings command is called. |
UserROIHeightDevLong | The memorized value of userROIHeight attribute when SaveCurrentSettings command is called. |
ChamberOffsetXDevDouble | the initial value of the ChamberOffsetX attribute |
ChamberOffsetYDevDouble | the initial value of the ChamberOffsetY attribute |
CentroidSaturationRegionSideDevLong | the initial value of the CentroidSaturationRegionSide attribute |
CentroidSaturationRegionThresholdDevLong | the initial value of the CentroidSaturationRegionThreshold attribute |
Updated:
The device class has been updated.
You are looking at this version now.
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.