This is historical information of device classes implemented in Diffractometer device server.
Use this link to find the valid information.
Development status:
Released
Information status: Updated
Contact:
Class Description
This class can be used to compute cristallography computation
Families: BeamlineComponents
Key words: Miscellaneous
Platform: All Platforms
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
Name | Description |
---|---|
AnglesIdxScalar: DevShort | — |
AutoUpdateFromProxiesScalar: DevBoolean | — |
WaveLengthScalar: DevDouble | — |
CrystalScalar: DevString | — |
AScalar: DevDouble | — |
AFitScalar: DevBoolean | — |
BScalar: DevDouble | — |
BFitScalar: DevBoolean | — |
CScalar: DevDouble | — |
CFitScalar: DevBoolean | — |
AlphaScalar: DevDouble | — |
AlphaFitScalar: DevBoolean | — |
BetaScalar: DevDouble | — |
BetaFitScalar: DevBoolean | — |
GammaScalar: DevDouble | — |
GammaFitScalar: DevBoolean | — |
UxScalar: DevDouble | — |
UxFitScalar: DevBoolean | — |
UyScalar: DevDouble | — |
UyFitScalar: DevBoolean | — |
UzScalar: DevDouble | — |
UzFitScalar: DevBoolean | — |
AStarScalar: DevDouble | — |
BStarScalar: DevDouble | — |
CStarScalar: DevDouble | — |
AlphaStarScalar: DevDouble | — |
BetaStarScalar: DevDouble | — |
GammaStarScalar: DevDouble | — |
SimulatedScalar: DevBoolean | — |
CrystalNamesSpectrum: DevString | — |
AxesNamesSpectrum: DevString | — |
pseudoAxesProxiesSpectrum: DevString | — |
AnglesImage: DevDouble | — |
AnglesDegeneratedImage: DevBoolean | — |
AnglesRangeCheckImage: DevBoolean | — |
ReflectionsImage: DevDouble | — |
ReflectionsAnglesImage: DevDouble | — |
UBImage: DevDouble | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
AbortInput: DevVoid Output: DevVoid |
Stops the movement of all axis driven by the Diffractometer |
AddNewCrystalInput: DevString Output: DevVoid |
Create a new crystal |
AddReflectionInput: DevVarDoubleArray Output: DevVoid |
This commands requires the definition of 1 reflection defined by (h,k,l ) coordinates. This coodinates are associated with the current angles configuration. TODO: d�taill� le commentaire reflections i.e : h, k, l, relevance, enable/disable |
AffineCrystalInput: DevString Output: DevDouble |
Compute affinement for the current crystal with available list of reflection. |
ComputeUInput: DevVarLongArray Output: DevVoid |
Compute Matrix U from two reflections |
ConfigureCrystalInput: DevVarDoubleArray Output: DevVoid |
Defines crystal lattice parameters. This information is mandatory for angles calculations. Angles units are degrees |
CopyCurrentCrystalAsInput: DevString Output: DevVoid |
Copy the current crytal as another name |
CopyReflectionToInput: DevVarDoubleStringArray Output: DevVoid |
Copy one reflection from the current crystal to another crystal |
DeleteCurrentCrystalInput: DevVoid Output: DevVoid |
Delete the current from this device |
GetCrystalParameterValuesInput: DevString Output: DevVarDoubleStringArray |
Return all values of a parameter for the current crystal |
LoadInput: DevVoid Output: DevVoid |
Load all crystals |
RemoveReflectionInput: DevShort Output: DevVoid |
This commands removes reflection from the current cristal. |
SaveInput: DevVoid Output: DevVoid |
Save all crystals |
SetCrystalParameterValuesInput: DevVarDoubleStringArray Output: DevVoid |
Double : min value, max value, affinement enable |
Pipes:
Properties:
Name | Description |
---|---|
TauConstantDevDouble | Definition of the Tau constant . Possible values are pi or 1 . Default : 1 |
RealAxisProxiesString[]Type | — |
LambdaAttributeProxyDevString | The name of the lambda attribute proxy. The diffractometer use it to read the lambda value from another Device |
DiffractometerTypeDevString | The Type of the diffractometer |
ProtectReflectionAxesDevBoolean | allow or not to change the values of the axes in the Reflections attribute. set this properties to false to allow writting on the axes values. |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You are looking at this version now.
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:22 Feb 2018, 2:23 p.m.