This is historical information of device classes implemented in TuneMeasurement device server.
Use this link to find the valid information.
Development status:
Released,
Release: release_1_2_4
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/BeamDiagnostics/TuneMeasurement
Contact:
Class Description
- Tune measurement device.
- This device computes tune measurement by getting its data from another device attribute (currently BPM or RF), computing a Fast Fourier Transform (FFT) on it with possible averaging, and extracting the maximal value of this FFT inside a predefined interval.
Families: BeamDiagnostics
Key words:
Language: Cpp
Contact:
Class interface
Attributes:
Name | Description |
---|---|
NuPeakSearchStartScalar: DevDouble | — |
NuPeakSearchEndScalar: DevDouble | — |
NuScalar: DevDouble | — |
NuInHigherIntervalScalar: DevBoolean | — |
NuRawScalar: DevDouble | — |
FFTNbPointsScalar: DevLong | — |
SkippedFirstSamplesScalar: DevUShort | — |
FFTAveragingScalar: DevUShort | — |
EstimComputTimeScalar: DevLong | — |
ComputationPeriodScalar: DevLong | — |
FFTWindowSizeScalar: DevLong | — |
NuRawMagnitudeScalar: DevDouble | — |
FFTabsSpectrum: DevDouble | — |
FFTordSpectrum: DevDouble | — |
FFTphaseSpectrum: DevDouble | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
StartInput: DevVoid Output: DevVoid |
Start the computation of the tune measure |
StopInput: DevVoid Output: DevVoid |
Stops the computation of the tune measure |
Pipes:
Properties:
Name | Description |
---|---|
SrcDeviceDevString | Device name where the data are read |
SrcDataAttrNameDevString | Attribute name read on SrcDevice for the data |
SrcSizeAttrNameDevString | Attribute name to configure the number of samples in SrcDataAttrName |
SrcSizeWriteEnabledDevBoolean | Tells if this device is allowed to control the SrcSizeAttrName, or if it can only read it |
SkippedFirstSamplesDevShort | The number of samples that are dropped in the beginning of the data src buffer, before computing the FFT |
WindowTypeDevString | The type of window applied to the input signal. Must be one of the following : RECTANGULAR, BLACKMAN, EXACT_BLACKMAN, HAMMING, HANN, FLATTOP, BLACKMAN_HARRIS_3, BLACKMAN_HARRIS_4, BLACKMAN_HARRIS_7, LOW_SIDELOBE |
FFTMinimalNbPointsDevLong | The minimal number of bins in the FFT. Must be a power of 2 (otherwise, rounded to the next power of 2 |
ComputationPeriodDevLong | The initial internal period in millisecond at which new tune measures are produced |
AutoStartDevBoolean | if set to `true`, the computation of the tune measure starts automatically when the device is launched |
FFTWindowSizeDevLong | The number of points in the src buffer that are used to compute the FFT |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:22 Feb 2018, 2:21 p.m.