Development status:
Released,
Release: Release_1_10
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Motion/MotorControllers/PI/PiezoPiE712
Contact:
Class Description
Families: Motion
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: Physik Instrumente (PI)
Product:
E712
Bus: Socket
Class interface
Attributes:
Name | Description |
---|---|
PositionScalar: DevDouble | — |
ServoModeScalar: DevLong | — |
ErrorScalar: DevString | — |
UnitLimitMinScalar: DevDouble | — |
UnitLimitMaxScalar: DevDouble | — |
VersionScalar: DevString | — |
VoltageScalar: DevDouble | — |
OverflowStatusScalar: DevUShort | — |
SlewRateScalar: DevLong | — |
WaveOffsetScalar: DevLong | — |
WaveAmplitudeScalar: DevLong | — |
WaveStartPointScalar: DevLong | — |
WaveSpeedUpDownScalar: DevLong | — |
WaveSegmentLengthScalar: DevLong | — |
WaveWaveLengthScalar: DevLong | — |
WaveTableRateScalar: DevLong | — |
ConversionScalar: DevDouble | Only defined for being used in Online in sweep scans for converting speed to position units/s |
SlewDoubleScalar: DevDouble | — |
WaveOutputCyclesScalar: DevLong | the number of wave generator cycles. IF 0, the waveform\nis output without period limitation until WGO |
ServoUpdateRateScalar: DevDouble | the update rate [s] |
WOSScalar: DevDouble | WOS, the offset of the generator |
FlagMoveByWaveGeneratorScalar: DevLong | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
MoveRelativeInput: DevDouble Output: DevLong |
— |
CheckDriftStabilityInput: DevDouble Output: DevDouble |
— |
StopMoveInput: DevVoid Output: DevVoid |
— |
ResetMotorInput: DevVoid Output: DevVoid |
Reset master unit. |
CalibrateInput: DevDouble Output: DevVoid |
Only for compatibility reasons. Does nothing. |
StartWaveGeneratorInput: DevVoid Output: DevVoid |
Starts wave generator with the waveform defined in the correspoding attributes |
StopWaveGeneratorInput: DevVoid Output: DevVoid |
Stops wave generator. |
DefineWaveformInput: DevVoid Output: DevVoid |
Define waveform with the corresponding attribute values. |
ReadWaveformInput: DevVoid Output: DevString |
Read positions of the defined waveform. |
Pipes:
Properties:
Name | Description |
---|---|
SocketDSDevString | — |
AxisNumberDevLong | Axis Number (from 1 to 3) |
Please log in to comment.
Generated
README
b'\nThe PiezoPiE712 class uses PiezoPiCtrl\n\n # ./Do.pl [nodeName]\n\ncreates a server and copies it to /usr/local/bin/server or the\nsame directory on nodeName. \n\n # make using_trunk=1\n\nmakes the server by using the trunk dirs as input\n\n # make\n\ncreates the server by using the current version dir\n\n\n\n'
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.