This is historical information of device classes implemented in ImgAnalogGrabber device server.

Use this link to find the valid information.

Development status: New development
Information status: Updated

Contact:



Class Description


The device grabs images from a NI1409 acquisition board

Families: Acquisition

Key words: - 2D

Language: Cpp

License:

Contact:

Class interface


Attributes:

Name Description
ActiveChannelScalar: DevUShort
ModeScalar: DevUShort
BlackRefLevelScalar: DevDouble
WhiteRefLevelScalar: DevDouble
ShutterDelayScalar: DevDouble
ExposureTimeScalar: DevDouble
RefreshingPeriodScalar: DevDouble
ImageImage: DevShort

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
AutoAdjustRefLevelsInput: DevVoid
Output: DevVoid
auto adjust the white reference level to adapt the dynamic of the image to the resolution
SetROIInput: DevVarULongArray
Output: DevVoid
specify a Region Of Interest in the image
FullROIInput: DevVoid
Output: DevVoid
resets any previously specified ROI
GetROIInput: DevVoid
Output: DevVarULongArray
gives the current ROI used
SaveCurrentSettingsInput: DevVoid
Output: DevVoid
saves the current configuration parameters to the Tango database
OpenInput: DevVoid
Output: DevVoid
opens and locks the hardware interface
CloseInput: DevVoid
Output: DevVoid
closes and unlock the video interface
StartInput: DevVoid
Output: DevVoid
launch the image acquisition
StopInput: DevVoid
Output: DevVoid
stops the video acquisition
ToggleImageFreezingInput: DevVoid
Output: DevVoid
None.

Pipes:

Properties:

Name Description
ActiveChannelDevShort
Channel0ModeDevShort
Channel0RefLevelBlackDevDouble
Channel0RefLevelWhiteDevDouble
Channel0ShutterDelayDevDouble
Channel0ShutterExposureDevDouble
Channel0SoftTrigPeriodDevDouble
Channel1ModeDevShort
Channel1RefLevelBlackDevDouble
Channel1RefLevelWhiteDevDouble
Channel1ShutterDelayDevDouble
Channel1ShutterExposureDevDouble
Channel1SoftTrigPeriodDevDouble
Channel2ModeDevShort
Channel2RefLevelBlackDevDouble
Channel2RefLevelWhiteDevDouble
Channel2ShutterDelayDevDouble
Channel2ShutterExposureDevDouble
Channel2SoftTrigPeriodDevDouble
Channel3ModeDevShort
Channel3RefLevelBlackDevDouble
Channel3RefLevelWhiteDevDouble
Channel3ShutterDelayDevDouble
Channel3ShutterExposureDevDouble
Channel3SoftTrigPeriodDevDouble
InterfaceNameDevString
UseAsyncGrabbingDevBoolean
AutoStartDevBoolean

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:22 Feb 2018, 2:17 p.m.