This is historical information of device classes implemented in Mar345 device server.

Use this link to find the valid information.

Development status: New development
Information status: Updated

Contact:



Class Description


The Mar345 device is used to control the MAR345 Image Plate Scanner Detector.
it uses the scan345 daemon to run. it write commands into a dedicated file, which is processed by the scan345 daemon and read logs/status on another dedicated file, which is written by the scan345 daemon

Families: Acquisition

Key words: 2D

Platform: Unix Like

Language: Cpp

License:

Contact:

Hardware


Manufacturer: Marresearch

Product:

Mar345

Bus: Ethernet

Class interface


Attributes:

Name Description
modeScalar: DevShort
modeStringScalar: DevString
pixelSizeScalar: DevFloat
saveFileNameScalar: DevString
directoryScalar: DevString
rootScalar: DevString
imageNumberScalar: DevShort
getImageScalar: DevBoolean
exposureTimeScalar: DevDouble
marSerialNumberScalar: DevString
marLogsSpectrum: DevString
marProgressLogsSpectrum: DevString
imageImage: DevULong
resizedImageImage: DevULong

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
ScanInput: DevVoid
Output: DevVoid
Start a scan (read) on the Mar345
EraseInput: DevVoid
Output: DevVoid
Start an erase on the Mar345
OpenCurrentImageInput: DevVoid
Output: DevVoid
Open the image corresponding to the Current Scan
OpenImageFileInput: DevString
Output: DevVoid
Open an image file, and display it inthe image attribute

Pipes:

Properties:

Name Description
MarLogDirDevString Directory for the command/spy files (ie: mar.com and mar.spy)
MarTablesDirDevString Directory for the tables files (ie: center2300.XXX, ...)

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:22 Feb 2018, 2:17 p.m.