This is historical information of device classes implemented in Ieee1394 device server.
Use this link to find the valid information.
Development status:
New development
Information status: Updated
Contact:
Class Description
- A generic device server for interfacing all FireWire cameras under Linux. It uses
- the dc1394 library for accessing the cameras.
Families: Acquisition
Key words: 2D
Language: Cpp
Contact:
Class interface
Attributes:
Name | Description |
---|---|
InfoScalar: DevString | — |
ExposureScalar: DevDouble | — |
RoiSpectrum: DevLong | — |
BinningSpectrum: DevShort | — |
WidthScalar: DevLong | — |
HeightScalar: DevLong | — |
FramesScalar: DevLong | — |
DepthScalar: DevShort | — |
FileParamsSpectrum: DevString | — |
FileFormatScalar: DevString | — |
VideoModeScalar: DevShort | — |
VideoModeTagScalar: DevString | — |
VideoModesSupportedSpectrum: DevString | — |
BayerMethodScalar: DevShort | — |
FrameRateScalar: DevDouble | — |
ImageImage: DevUChar | — |
ImageFormatScalar: DevString | — |
ImageCounterScalar: DevLong | — |
JpegImageSpectrum: DevUChar | — |
JpegQualityScalar: DevShort | — |
JpegCompressionScalar: DevBoolean | — |
AutoFeaturesScalar: DevBoolean | — |
RelativeUnitsScalar: DevBoolean | — |
BrightnessScalar: DevDouble | — |
SharpnessScalar: DevDouble | — |
WhiteBalanceScalar: DevDouble | — |
HueScalar: DevDouble | — |
SaturationScalar: DevDouble | — |
GammaScalar: DevDouble | — |
GainScalar: DevDouble | — |
IrisScalar: DevDouble | — |
FocusScalar: DevDouble | — |
TemperatureScalar: DevDouble | — |
TriggerDelayScalar: DevDouble | — |
WhiteShadingScalar: DevDouble | — |
TriggerScalar: DevShort | — |
TriggerModeScalar: DevShort | — |
TriggerPolarityScalar: DevShort | — |
TriggerSourceScalar: DevShort | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
StartInput: DevVoid Output: DevVoid |
start camera exposing |
StopInput: DevVoid Output: DevVoid |
stop camera exposing |
ResetInput: DevVoid Output: DevVoid |
reset camera roi |
WriteFileInput: DevVoid Output: DevVoid |
write image to file in the selected format, use the file parameters to generate file name |
LiveInput: DevVoid Output: DevVoid |
put camera in live mode |
Pipes:
Properties:
Name | Description |
---|---|
Camera_numberDevLong | number of camera on the ieee1394 bus (starting from 0 |
Camera_id_lowDevLong | unique ieee1394 camera id - low 32 bits |
Camera_id_highDevLong | Unique ieee1394 camera id - high 32 bits |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:22 Feb 2018, 2:15 p.m.