Class Description


Families: Acquisition

Key words: 2D

Platform: All Platforms

Language: Cpp

License:

Contact:

Hardware


Manufacturer: none

Bus: Ethernet

Class interface


Attributes:

Name Description
DeviceIdScalar: DevLong
NumberOfChipsScalar: DevLong
NumberOfRowsScalar: DevLong
ExposureTimeScalar: DevDouble
NumberOfFramesScalar: DevLong
DirectoryScalar: DevString
FileNameScalar: DevString
ChipBoardIDScalar: DevString
InterfaceNameScalar: DevString
AcquisitionTypeScalar: DevUShort
AcquisitionTypesScalar: DevString
MaskBitFileAsciiScalar: DevString
TestBitFileAsciiScalar: DevString
LowTHSFileAsciiScalar: DevString
HighTHSFileAsciiScalar: DevString
WriteFilesScalar: DevBoolean
AcquisitionModeScalar: DevLong
PolarityScalar: DevBoolean
BiasVoltageScalar: DevDouble
SaveBinaryScalar: DevBoolean
AppendScalar: DevBoolean
FrameDataTypeScalar: DevLong
RepeatScalar: DevUShort
DelayScalar: DevDouble
MedipixTypeScalar: DevString
DACValuesAsStringScalar: DevString
FlipHorizontalScalar: DevBoolean
FlipVerticalScalar: DevBoolean
RotateScalar: DevDouble
DACNamesSpectrum: DevString
DACValuesSpectrum: DevUShort
DACValuesAnalogSpectrum: DevDouble
InterfaceSpecificInfosSpectrum: DevString
AcquisitionModesSpectrum: DevString

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
GetDACValueInput: DevString
Output: DevUShort
None.
LoadBinaryPixelsCfgInput: DevString
Output: DevVoid
None.
LoadHighThresholdsInput: DevString
Output: DevVoid
None.
LoadLowThresholdsInput: DevString
Output: DevVoid
None.
LoadMaskBitsInput: DevString
Output: DevVoid
None.
LoadTestBitsInput: DevString
Output: DevVoid
None.
PerformAcquisitionInput: DevVoid
Output: DevVoid
None.
PerformFrameAcquisitionInput: DevVoid
Output: DevVoid
None.
SetDACValueInput: DevString
Output: DevDouble
Sets a DAC value. The input argument must have the form .
StartTriggerInput: DevVoid
Output: DevVoid
None.
StopTriggerInput: DevVoid
Output: DevVoid
None.
PerformIntegralAcquisitionInput: DevVoid
Output: DevVoid
None.
ResetPixelConfigurationInput: DevVoid
Output: DevVoid
None.
SetDACsToDefaultInput: DevVoid
Output: DevVoid
None.
AbortInput: DevVoid
Output: DevVoid
None.
SaveConfigInput: DevVoid
Output: DevVoid
None.

Pipes:

Properties:

Name Description
StorageDevString Storage type (FILE_STORE, or TANGO_STORE)\nTANGO_STORE must be given like this `TANGO_STORE:some/tango/device`
ConfigDirectoryDevString

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.