This is historical information of device classes implemented in PiezoPiE725 device server.
Use this link to find the valid information.
Development status:
Released,
Release: Release_1_0
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Motion/MotorControllers/PI/PiezoPiE725
Contact:
tnunez@mail.desy.de
Class Description
Families: Motion
Key words:
Platform: Unix Like
Language: Cpp
License: GPL
Contact: tnunez@mail.desy.de
Hardware
Manufacturer: Physik Instrumente (PI)
Product:
E725
Bus: Ethernet
Class interface
Attributes:
Name | Description |
---|---|
ServoModeScalar: DevLong | — |
ErrorScalar: DevString | — |
UnitLimitMinScalar: DevDouble | Software minimum limit |
UnitLimitMaxScalar: DevDouble | — |
VersionScalar: DevString | — |
SettleWindowScalar: DevLong | Settle window for close loop operation, |
SettleTimeScalar: DevDouble | Settle time for close loop operation |
SlewRateScalar: DevDouble | — |
PositionScalar: DevDouble | — |
HardLimitMaxScalar: DevDouble | Maximum commandable position |
HardLimitMinScalar: DevDouble | Minimum commandable position |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
MoveRelativeInput: DevDouble Output: DevLong |
— |
CheckDriftStabilityInput: DevDouble Output: DevDouble |
— |
StopMoveInput: DevVoid Output: DevVoid |
— |
ResetMotorInput: DevVoid Output: DevVoid |
Reset master unit. |
CalibrateInput: DevDouble Output: DevVoid |
Only for compatibility reasons. Does nothing. |
Pipes:
Properties:
Name | Description |
---|---|
SocketDSDevString | — |
AxisNumberDevLong | Axis Number (from 1 to 3) |
README
b'\nThe PiezoPiE725 class uses PiezoPiCtrl\n\n # ./Do.pl [nodeName]\n\ncreates a server and copies it to /usr/local/bin/server or the\nsame directory on nodeName. \n\n # make using_trunk=1\n\nmakes the server by using the trunk dirs as input\n\n # make\n\ncreates the server by using the current version dir\n\n\n\n'
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.