This is historical information of device classes implemented in BT500 device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
- handles generic BT500 cryogeenic temperature controller from Air Liquide
- (through serial line)
Families: Temperature
Key words:
Language: Cpp
Contact:
Class interface
Attributes:
Name | Description |
---|---|
setpointScalar: DevDouble | — |
TC1Scalar: DevDouble | — |
TC2Scalar: DevDouble | — |
TC3Scalar: DevDouble | — |
TC4Scalar: DevDouble | — |
deadbandScalar: DevDouble | — |
pumpModeAutomaticScalar: DevBoolean | — |
pumpManualSpeedScalar: DevLong | — |
regulationChannelScalar: DevLong | — |
ovenMaxPowerScalar: DevShort | — |
ovenPowerPercentScalar: DevShort | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
ExecLowLevelCommandInput: DevString Output: DevString |
None. |
ModePAPInput: DevVoid Output: DevVoid |
switches the BT500 from MAIN Menu to PAP Menu ( PAS A PAS, STEP BY STEP Menu) current Mode must be REMOTE, and Menu must be MAIN Menu |
ModeREGInput: DevVoid Output: DevVoid |
switches the BT500 from PAP Menu to REG Menu (REGulation Menu) current Mode must be REMOTE, and Menu must be PAP Menu |
RETInput: DevVoid Output: DevVoid |
If in REG Menu returns to PAP Menu if in PAP Menu returns to Main Menu Must be in REMOTE Mode |
LocalInput: DevVoid Output: DevVoid |
Returns to Local Command Mode (the touch screen on the front panel of the BT500) Must be in REMOTE Mode To switch to Remote Mode again the only way is to use the on the front panel of the BT500 |
StopInput: DevVoid Output: DevVoid |
The device returns to STANDBY State |
ResetInput: DevVoid Output: DevVoid |
resets after a fault |
ModeRGUInput: DevVoid Output: DevVoid |
sends the BT500 directly to RGU mode (Soleil working page) |
Pipes:
Properties:
Name | Description |
---|---|
SerialLineUrlDevString | Tango name of the Serial Device for Communication |
PeriodDevLong | periodic exec period in ms |
ReadTimeOutDevLong | timeout for reading |
TimeInDeadbandDevLong | time in deadband is used for State : when the temperature is inside deadband (abs (setpoint - temperature) < deadband) more than TimeInDeadband, the setpoint is considered as reached : state STANDBY otherwise RUNNING default : 60 |
ChannelsInUseDevString | temperature channel used The device will read only the channels really used for example the BT500 comes with 2 temperature chann and on option with 2 more temperature channels for 2 channels : set property to 12 for 3 channels : 123 or 124 for 4 channels : 1234 |
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:20 Apr 2017, 1:18 p.m.