This is historical information of device classes implemented in NovelecElectrometer device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
- This class allows you to control all MCCE-2 Novelec electrometers
- through a Serial bus.
- Supported types : Novelec Electrometers : MCCE2
Families: MeasureInstruments
Key words: - MCCE
Platform: All Platforms
Language: Cpp
Contact:
Hardware
Manufacturer: SAPHYMO
Product:
MCCE-2
Bus: Serial Line
Class interface
Attributes:
Name | Description |
---|---|
electrometerChannelScalar: DevUShort | — |
range1Scalar: DevString | — |
range2Scalar: DevString | — |
Commands:
Name | Description |
---|---|
LocalInput: DevVoid Output: DevVoid |
None. |
RemoteInput: DevVoid Output: DevVoid |
None. |
ResetInput: DevVoid Output: DevVoid |
None. |
ClearRegistersInput: DevVoid Output: DevVoid |
None. |
GetRangeInput: DevVoid Output: DevString |
None. |
SetRangeInput: DevString Output: DevVoid |
None. |
GetModeInput: DevVoid Output: DevString |
None. |
GetPolarityInput: DevVoid Output: DevString |
None. |
SetPolarityInput: DevString Output: DevVoid |
None. |
GetHzFilterInput: DevVoid Output: DevShort |
None. |
SetHzFilterInput: DevShort Output: DevVoid |
None. |
GetGainInput: DevVoid Output: DevShort |
None. |
SetGainInput: DevUShort Output: DevVoid |
None. |
GetElectrometerTypeStrInput: DevUShort Output: DevString |
None. |
StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
RangeUPInput: DevVoid Output: DevVoid |
None. |
RangeDOWNInput: DevVoid Output: DevVoid |
None. |
SetZeroVFFunctionInput: DevVoid Output: DevVoid |
None. |
SetOffsetZeroV1FunctionInput: DevVoid Output: DevVoid |
None. |
SetLeakageZeroV2FunctionInput: DevVoid Output: DevVoid |
None. |
SetTestFunctionInput: DevVoid Output: DevVoid |
None. |
SetMeasureFunctionInput: DevVoid Output: DevVoid |
None. |
MCCE2_ONInput: DevVoid Output: DevVoid |
None. |
MCCE2_OFFInput: DevVoid Output: DevVoid |
None. |
Pipes:
Properties:
Name | Description |
---|---|
CommunicationLinkNameDevString | The name of the device which manage the communication. |
Electrometer1AddressDevShort | The first electrometer address configured. Note : if not connected, push 0 or let empty the property. |
Electrometer2AddressDevShort | The second electrometer address configured. Note : if not connected, push 0 or let empty the property. |
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:20 Apr 2017, 1:11 p.m.