This is historical information of device classes implemented in RetrigAO device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
Perform continuous anolog ouput (waveform generation) on the selected outputs.
Families: InputOutput
Key words: - ADLINK
Platform: All Platforms
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
Name | Description |
---|---|
bufferDepthScalar: DevUShort | — |
errorCounterScalar: DevDouble | — |
useBoardFifoScalar: DevShort | — |
channel0EnableScalar: DevShort | — |
channel1EnableScalar: DevShort | — |
channel2EnableScalar: DevShort | — |
channel3EnableScalar: DevShort | — |
channel4EnableScalar: DevShort | — |
channel5EnableScalar: DevShort | — |
channel6EnableScalar: DevShort | — |
channel7EnableScalar: DevShort | — |
frequencyScalar: DevDouble | — |
channel0Spectrum: DevDouble | — |
channel1Spectrum: DevDouble | — |
channel2Spectrum: DevDouble | — |
channel3Spectrum: DevDouble | — |
channel4Spectrum: DevDouble | — |
channel5Spectrum: DevDouble | — |
channel6Spectrum: DevDouble | — |
channel7Spectrum: DevDouble | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
StartInput: DevVoid Output: DevVoid |
start the generation. |
StopInput: DevVoid Output: DevVoid |
stop the generation. |
SetAOScaledDataInput: DevVarDoubleStringArray Output: DevVoid |
Give one period of the signal to generated of a specified channel in volts. |
Pipes:
Properties:
Name | Description |
---|---|
FrequencyDevDouble | The output frequency (the rate the samples are outputed). |
BoardNumDevShort | The number of the board in the chassis cPCI. |
TriggerModeDevShort | Trigger mode: POST trigger or DELAY trigger. |
TriggerSourceDevShort | The trigger source.The possible values are internal trigger INTRIG, digital trigger DTRIG or analog trigger ATRIG. |
ATRIGSelectionDevShort | select the type of analog trigger. Can be BELOW (trigger occurs below ATRIGLevel) or can be ABOVE (trigger occurs above ATRIGLevel). |
ATRIGLevelDevDouble | The analog trigger level in volts. |
DTRIGPolarityDevShort | The edges on which the trigger are detected. Can be RISING or FALLING. |
AORefADevDouble | The value of the reference voltage gave on pin AORefA. |
AORefBDevDouble | The value of the reference voltage gave on pin AORefB. |
PolarityDevShort | BP for unipolar outputs or UP for bipolar outputs. |
AORefSourceDevShort | Select the internal reference (10.0 volts) with INTERN or the external references AORefA and AORefB with EXTERN. |
Channel0EnableDevShort | 1 if enable channel 0, 0 otherwise. |
Channel1EnableDevShort | 1 if enable channel 1, 0 otherwise. |
Channel2EnableDevShort | 1 if enable channel 2, 0 otherwise. |
Channel3EnableDevShort | 1 if enable channel 3, 0 otherwise. |
Channel4EnableDevShort | 1 if enable channel 4, 0 otherwise. |
Channel5EnableDevShort | 1 if enable channel 5, 0 otherwise. |
Channel6EnableDevShort | 1 if enable channel 6, 0 otherwise. |
Channel7EnableDevShort | 1 if enable channel 7, 0 otherwise. |
DelayDevShort | If trigger mode is delay, configure the delay in seconds. |
BufferDepthDevShort | The buffer depth for one channel |
Channel0WaveformDouble[]Type | The waveform for channel 0 (attribute persistency). |
Channel1WaveformDouble[]Type | The waveform for channel 1 (attribute persistency). |
Channel2WaveformDouble[]Type | The waveform for channel 2 (attribute persistency). |
Channel3WaveformDouble[]Type | The waveform for channel 3 (attribute persistency). |
Channel4WaveformDouble[]Type | The waveform for channel 4 (attribute persistency). |
Channel5WaveformDouble[]Type | The waveform for channel 5 (attribute persistency). |
Channel6WaveformDouble[]Type | The waveform for channel 6 (attribute persistency). |
Channel7WaveformDouble[]Type | The waveform for channel 7 (attribute persistency). |
FilePathDevString | The path to waveforms persistancy files |
ConversionSourceDevShort | Set the AO conversion signal source (i.e. DAC sampling source). Use one of the following: INTERNAL, EXTSAMPLING. |
README
b'//-============================================================\n//\n// This class has been generated by POGO\n// (Program Obviously used to Generate tango Object)\n//\n// (c) - Software Engineering Group - ESRF\n//=============================================================\n\n\nFiles generated:\n===============\nRetrigAO.cpp: Source code for the RetrigAO class and its commands.\n This class is derived from DeviceImpl_2 class.\n It represents the CORBA servant obbject which\n will be accessed from the network.\n All commands which can be executed on the\n RetrigAO are implemented in this file.\n\nRetrigAO.h: Include for the RetrigAO class.\n Server class prototypes and descriptions.\n\nRetrigAOClass.cpp: A singleton class derived fromRetrigAO.\n It implements the command list and all properties\n and methods required by the RetrigAO once per process\n\nRetrigAOClass.h:\tInclude for the RetrigAOClass root class.\n This class is represents the singleton class for\n the RetrigAO device class.\n It contains all properties and methods which the \n RetrigAO requires only once e.g. the commands.\n\nmain.cpp:\t\tC++ source for a TANGO device server main.\n The main rule is to initialise (and create) the Tango\n system and to create the DServerClass singleton.\n The main should be the same for every Tango device server.\n\nClassFactory.cpp:\tC++ source for the class_factory method of the DServer\n device class. This method is responsible to create\n all class singletin for a device server. It is called\n at device server startup\n'
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.