This is historical information of device classes implemented in RetrigAI device server.

Use this link to find the valid information.

Development status: Released
Information status: New

Contact:



Class Description


Perform infinite retriggered analog input acquisition simultaneously on four channels.
The device is available for boards SAI_2005 and SAI_2010.

Families: InputOutput

Key words: ADLINK

Language: Cpp

License:

Contact:

Class interface


Attributes:

Name Description
totalNbPointScalar: DevDouble
dataCounterScalar: DevLong
timeoutCounterScalar: DevLong
overrunCounterScalar: DevLong
errorCounterScalar: DevLong
frequencyScalar: DevDouble
bufferDepthScalar: DevDouble
continuousAcquisitionScalar: DevBoolean
generateNexusFileScalar: DevBoolean
nexusFilePathScalar: DevString
channel0Spectrum: DevDouble
channel1Spectrum: DevDouble
channel2Spectrum: DevDouble
channel3Spectrum: DevDouble
averageChannel0Spectrum: DevDouble
averageChannel1Spectrum: DevDouble
averageChannel2Spectrum: DevDouble
averageChannel3Spectrum: DevDouble

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartInput: DevVoid
Output: DevVoid
Start acquisition.
StopInput: DevVoid
Output: DevVoid
Stop acquisition.
CalibrateInput: DevVoid
Output: DevVoid
Calibrate hardware.
ResetInput: DevVoid
Output: DevVoid
Resets all channels data.

Pipes:

Properties:

Name Description
BoardTypeDevShort The board type ( the possible values are SAI_2005, SAI_2010).
BoardNumDevShort The number of the board in the cPCI chassis (between 0 and 7).
InputRange0DevShort The input range for channel 0 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ).
InputRange1DevShort The input range for channel 1 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ).
InputRange2DevShort The input range for channel 2 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ).
InputRange3DevShort The input range for channel 3 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ).
TimeoutDevDouble The time to wait for incoming data before generating a timout. In seconds.
TriggerModeDevShort The trigger mode. Can be a POST trigger and data is acquired just after the received trigger. Can be a DELAY trigger and data is acquired after a certain delay.
TriggerSourceDevShort To choose analog (ATRIG) or digital trigger(DTRIG).
ATRIGSelectionDevShort To select the type of analog trigger. The trigger can be generated when the analog trigger passes below a level or above a level. The possible values are BELOWand ABOVE.
ATRIGLevelDevDouble The level of the analog trigger in volts.
DTRIGPolarityDevShort The digital level polarity. It can be detected on rising edge or falling edge. The possible values are RISING or FALLING.
DelayDevDouble The delay after a Delay trigger in seconds.
ConversionSourceDevShort Set the AI conversion signal source (i.e. DAC sampling source). Use one of the following: INTERNAL, EXTSAMPLING.
AutoStartDevBoolean Start the acquisition when starting the device.
ContinuousAcquisitionDevBoolean Allows the acquisition to run indefinitely.
MemorizedGenerateNexusFileDevBoolean Allows storage of acquired data into Nexus files.
MemorizedNexusFilePathDevString Contains the last value of the nexusFilePath attribute. [default value =d:\\target]

README

b'//-============================================================\n//\n// This class has been generated by POGO\n// (Program Obviously used to Generate tango Object)\n//\n// (c) - Software Engineering Group - ESRF\n//=============================================================\n\n\nFiles generated:\n===============\nRetrigAI.cpp: Source code for the RetrigAI class and its commands.\n This class is derived from DeviceImpl_2 class.\n It represents the CORBA servant obbject which\n will be accessed from the network.\n All commands which can be executed on the\n RetrigAI are implemented in this file.\n\nRetrigAI.h: Include for the RetrigAI class.\n Server class prototypes and descriptions.\n\nRetrigAIClass.cpp: A singleton class derived fromRetrigAI.\n It implements the command list and all properties\n and methods required by the RetrigAI once per process\n\nRetrigAIClass.h:\tInclude for the RetrigAIClass root class.\n This class is represents the singleton class for\n the RetrigAI device class.\n It contains all properties and methods which the \n RetrigAI requires only once e.g. the commands.\n\nmain.cpp:\t\tC++ source for a TANGO device server main.\n The main rule is to initialise (and create) the Tango\n system and to create the DServerClass singleton.\n The main should be the same for every Tango device server.\n\nClassFactory.cpp:\tC++ source for the class_factory method of the DServer\n device class. This method is responsible to create\n all class singletin for a device server. It is called\n at device server startup\n'

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:20 Apr 2017, 1:09 p.m.