This is historical information of device classes implemented in SIS3820MCS device server.
Use this link to find the valid information.
Development status:
Released,
Release: Release_1_6
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/CounterTimer/SIS3820MCS
Contact:
Class Description
Tango Class for the SIS3820 counter used in MultiChannelMode.
Families: CounterTimer
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: Struck
Product:
SIS3820
Bus: VME
Class interface
Attributes:
Name | Description |
---|---|
NbChannelsScalar: DevLong | Nb of channels to be readout |
NbAcquisitionsScalar: DevLong | Nb of acquisitions to be readout. Set to 0 if trigger in continuous mode. |
PresetScalar: DevLong | MCS preset value |
FlagMCSSetScalar: DevLong | — |
AcquiredTriggersScalar: DevLong | Number of triggers received. |
CountsArrayImage: DevLong | Readout of the MCS. It is one array of efective dimension\nNbChannel*NbAcquisitions. These has to be used for\n extracting the readout of a given channel. The counts for all \nchannels in one acquisition are consecutive. For exemplo if the\narray values are: 1, 3, 5, 6, 2, 8, for 2 channels in 3 acquisitions, the\nreadout of the first channel would be: 1, 5, 2 and of the\n second: 3, 6, 8. |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
ClearSetupMCSInput: DevVoid Output: DevLong Completion status |
Clear MCS memory and setup for receiving new external triggers. |
ReadMCSInput: DevVoid Output: DevLong Completion status |
Read Multi Channel Scaler |
Pipes:
Properties:
Name | Description |
---|---|
MaxNbChannelsDevLong | Maximum number of channels en Multi Channel Scaler |
MaxNbAcquisitionsDevLong | Maximum number of acquisitions to be readout for every channel |
BaseDevULong | VME base address. Default: 0x38000000 (939524096) |
SimulationModeDevULong | 0 real mode, 1 simulation mode |
FlagExternalTriggerDevLong | Set to 1 if the MCS is trigger externally. 0 for software trigger. |
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.